The Basler microEnable 5 marathon ACX-QP is a PCIe image acquisition device that allows the connection of up to four CoaXPress cameras with a bandwidth of 25 Gbit/s. The interface is CoaXPress (CXP-6) with 4 camera ports, each listed at 6.25 Gbit/s, for 25 Gbit/s total. The host bus is PCIe 2.1 x4 with DMA1800, and power over cable is PoCXP (13W/24V per connector).
The on-board processor is a Xilinx Kintex7 XC7K160T, whose FPGA programming is listed as not programmable, and the card carries 1 GByte of DDR3-RAM. Software access is through the .net interface and the Framegrabber SDK. The I/O is listed as 12 in/10 out (max.), TTL or opto-coupled, with differential or single-ended signals depending on configuration.
Supported operating systems are Linux 64-Bit, Windows 11 / 10 (64-Bit) and Windows 11 / 10 (32-Bit). The card is PCIe standard height, half length (167.64 mm length x 111.15 mm height) and weighs 200 g. The operating temperature entry reads "50° (0 LFM*), 60° (100 LFM*) FPGA operating temperature: 0°C to 85°C, * LFM = Linear Feet per Minute, unit for measuring airflow velocity".
Best for
CoaXPress CXP-6 installations with up to four cameras on one PCIe card
Cameras powered over the coax cable through PoCXP (13W/24V per connector)
Host-software processing pipelines built on the .net interface or the Framegrabber SDK
Machines that use up to 12 inputs and 10 outputs of TTL or opto-coupled I/O on the grabber
Windows 11 / 10 (64-Bit or 32-Bit) and Linux 64-Bit vision PCs
Selection notes
The card serves CoaXPress (CXP-6) cameras: each of the 4 ports is listed at 6.25 Gbit/s, for 25 Gbit/s total.
The host slot must be PCIe with room for a PCIe standard height, half length card; the bus is PCIe 2.1 x4, DMA1800.
The FPGA is listed as not programmable, so plan application-specific image processing in your host software.
The operating temperature is given with an airflow figure: "50° (0 LFM*), 60° (100 LFM*) FPGA operating temperature: 0°C to 85°C, * LFM = Linear Feet per Minute, unit for measuring airflow velocity". Check it against the airflow inside your PC chassis.
The 12 in/10 out (max.) I/O can be TTL or opto-coupled, differential or single-ended depending on configuration; check in the manufacturer datasheet how it must be set up before wiring.
Specifications: General
Brand
Basler
Card type
Frame grabber
Specifications: Performance
Total bandwidth
25 Gbit/s total (6.25 Gbit/s per port)
On-board processing
Xilinx Kintex7 XC7K160T (FPGA programming: not programmable)
On-board memory
1 GByte DDR3-RAM
Specifications: Interface
Interface
CoaXPress (CXP-6)
Camera ports
4
PC bus
PCIe 2.1 x4, DMA1800
Trigger / GPIO
12 in/10 out (max.), TTL or opto-coupled; differential or single-ended signals (configuration dependent)
Specifications: Electrical
Power over cable (PoE / PoCXP / PoCL)
PoCXP (13W/24V per connector)
Specifications: Environment
Operating temperature
50° (0 LFM*), 60° (100 LFM*) FPGA operating temperature: 0°C to 85°C, * LFM = Linear Feet per Minute, unit for measuring airflow velocity
Specifications: Software
Operating systems
Linux 64-Bit; Windows 11 / 10 (64-Bit); Windows 11 / 10 (32-Bit)
Software / API
.net interface; Framegrabber SDK
Specifications: Mechanical
Dimensions
PCIe Standard height, half length card: 167.64 mm length x 111.15 mm height
Weight
200 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Matched automatically by: camera interface matches the card (coaxpress) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this card: CoaXPress (CXP-6) · 4 camera ports.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Up to four, via 4 camera ports of CoaXPress (CXP-6), each at 6.25 Gbit/s, for 25 Gbit/s total.
Yes, power over cable is listed as PoCXP (13W/24V per connector).
No. The Xilinx Kintex7 XC7K160T is listed with FPGA programming: not programmable. The card has 1 GByte of DDR3-RAM.
A .net interface and the Framegrabber SDK, on Linux 64-Bit, Windows 11 / 10 (64-Bit) and Windows 11 / 10 (32-Bit).