Opto Engineering PTCP film-on-glass — checkerboard calibration pattern (film-on-glass photomask on soda lime glass); 3 plate sizes / 5 part numbers: plate 180 × 140 to 300 × 240 mm × 5 mm, active area 167.4 × 129.6 mm to 286.2 × 226.8 mm, squares 1.35–2.20 mm; accuracy Grade 4.
Brand
Opto Engineering
Pattern
Checkerboard (1.35 / 2.20 mm squares)
Pattern area
167.4 × 129.6 mm to 286.2 × 226.8 mm active area (W × H), by part number
Film-on-glass suits coarser pixel scales, and the tolerance shows why. ±(9.6 µm + 0.015 µm/mm × length) is 9.6 + 0.015 × 167.4 ≈ 12.1 µm across the smallest active width and 9.6 + 0.015 × 286.2 ≈ 13.9 µm across the largest. At an example 39 µm per pixel (160 mm over 4096 px) that is 0.3 to 0.4 px. At 10 µm per pixel it would exceed a pixel, and the Class 2 chrome-on-glass PTCP-S1-HR1-C is the better target. Class and grade labels differ between mask types, so compare tolerance formulas, not labels.
There are five part numbers on three plate sizes (180 × 140, 245 × 196 and 300 × 240 mm) of 5 mm soda lime glass, with 1.35 mm or 2.20 mm squares, for TC CORE PLUS and TCHR CORE PLUS lenses. No certificate is supplied. Photographic emulsion is typically softer than chrome, so clean it gently.
Best for
Calibrating TC CORE PLUS and TCHR CORE PLUS lenses at coarse scales of tens of micrometres per pixel, where 12 to 14 µm of target tolerance is a fraction of a pixel.
Routine recalibration and set-up checks where no traceability certificate is needed and the thicker 5 mm plate is stiffer in handling.
Fields close to 280 mm wide: PTCP-L1-HR1-P has the largest active area, 286.2 × 226.8 mm, and PTCP-L1-LR1-P adds 2.20 mm squares that stay easy to detect at coarse pixel scales.
Selection notes
Compare 12 to 14 µm with your pixel size. Below roughly 10 µm per pixel the tolerance exceeds a pixel and a chrome plate is the better choice.
The active area must cover the field of view: a 270 × 215 mm field fits PTCP-L1-LR1-P (281.6 × 228.8 mm), while PTCP-M1-HR1-P (237.6 × 189.0 mm) is too small.
If an audit requires traceability, this version cannot supply it: the chrome PTCP part numbers ship with a certificate.
Specifications: General
Brand
Opto Engineering
Pattern
Checkerboard (1.35 / 2.20 mm squares)
Compatible with
Opto Engineering TC CORE PLUS series, TCHR CORE PLUS series
Specifications: Geometry
Pattern area
167.4 × 129.6 mm to 286.2 × 226.8 mm active area (W × H), by part number
180 × 140 × 5 mm / 245 × 196 × 5 mm / 300 × 240 × 5 mm (W × H × thickness, by size)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Pattern area ●
Pattern accuracy
Dimensions ●
Compatible with ●
Availability
PTCP-S1-HR1-P — 180 × 140 mm plate, active area 167.4 × 129.6 mm, 1.35 mm squares, Grade 4 Base
Same grid, plate sizes and active areas, but film on 5 mm glass instead of chrome on 3 mm glass, no certificate, and a wider tolerance: about 12.1 µm over 167.4 mm (9.6 + 0.015 × 167.4) against about 2.9 µm (1.6 + 0.008 × 167.4) for the Class 2 chrome PTCP-S1-HR1-C. The other chrome part numbers are Grade B, without published figures.
The M1 plates, PTCP-M1-LR1-P (237.6 × 184.8 mm, 2.20 mm squares) and PTCP-M1-HR1-P (237.6 × 189.0 mm, 1.35 mm squares), are the smallest that cover it. Choose the square size from your pixel scale.
small: 26 cm × 18 cm; large: 39 cm × 27 cm; extra large: 52 cm × 36 cm (grid area)
3D Cameras: Basler STA-100-547M-082609-W, Basler Stereo Camera rc_visard 160m-6, Basler Stereo Camera rc_visard 160c, Basler Stereo Camera rc_visard 65m, Basler Stereo Camera rc_visard 65c, Basler STA-100-547C-082609-W, Basler Stereo Camera rc_visard 160m, Basler STA-200-547C-082616-W +3 more; Application Software: Basler 3D SilhouetteMatch, Basler 3D ItemPickAI, Basler 3D ItemPick, Basler 3D BoxPick, Basler 3D TagDetect, Basler 3D SilhouetteMatchAI, Basler 3D CADMatch
167.4 × 129.6 mm to 286.2 × 226.8 mm active area (W × H), by part number
Opto Engineering TC CORE PLUS series, TCHR CORE PLUS series
Class 2 (chrome-on-glass): tolerance ±(1.6 µm + 0.008 µm/mm × length); min. feature / spacing 0.8 µm; Grade B (maker's accuracy grade; no tolerance figures for it on the page)
Class 1 (chrome-on-glass): tolerance ±(6.4 µm + 0.016 µm/mm × length); min. feature / spacing 1.4 µm; Class 2 (chrome-on-glass): tolerance ±(1.6 µm + 0.008 µm/mm × length); min. feature / spacing 0.8 µm; Grade B (maker's accuracy grade; no tolerance figures for it on the page)