Fixed, handheld and logistics code readers
How to choose laser or imager and fixed or handheld readers, and size conveyor and tunnel reading from belt speed, code density and depth of field.
Laser or imager
A laser reader sweeps a spot along a line and decodes the reflected signal. Fixed-mount models typically deliver several hundred to over a thousand scans per second, have long reading ranges, and read high-contrast 1D labels well. Limits are clear: no matrix codes such as Data Matrix or QR, no DPM, no image for diagnosing failed reads, and in most designs a motor and mirror that eventually wear. Orientation also matters, since the line must cross all the bars, although multiple heads or reconstruction features that piece together fragments can widen tolerance.
An imager captures a picture and decodes every symbology it supports at any in-plane angle, reads several codes per image, and in many models can store images of failed reads, which is a major advantage when troubleshooting. Its costs are sensitivity to focus and motion blur, a need for strong illumination at speed, and resolution that is spread across the whole field of view. For new installations with any 2D code present or likely, the imager is the default. Laser remains reasonable for existing 1D-only flows with known label formats, and for long-range 1D jobs.
If you do choose laser, check its class against site requirements, typically IEC 60825-1 class 1 or 2, and read the reading-field diagram, which relates X-dimension to the range of distance. Mount it about 10-15° off perpendicular to avoid the specular return from glossy labels. The guide on 2D and DPM readers goes deeper into pixels per module and DPM lighting.
- Choose an imager when: 2D codes or DPM are present or likely, orientation is random, you want failure images, or several codes per item must be read.
- Choose a laser when: the flow is 1D-only, the format and orientation are known, or the read is long-range.
- Either way: test real labels at real speed, including the worst-printed ones.
Fixed-mount or handheld, corded or cordless
The first question is whether a person is in the loop. Fixed-mount readers suit automated flows: they are triggered by a sensor or read continuously, connect to a PLC or host, and repeat the same geometry each time. Handheld readers suit manual tasks such as goods-in, kitting, rework, spot checks and anything where the code's position varies too much to automate. The operator also acts as an adaptive positioner, altering angle and distance until the code reads, which is a real advantage on difficult marks. Hands-free cradles and presentation stands sit in between, for stations where items are brought to the reader.
Corded handhelds, usually USB and sometimes serial, need no battery and no pairing, and suit fixed workstations where a cable is not a hazard. Cordless models link by Bluetooth or another radio to a base station or directly to a host. They suit mobile tasks and long reach, but add charging, battery ageing and radio coverage to your maintenance scope. Practical range is typically tens of metres, less with metal racks or machinery in the way. Check how many readers one base supports, what happens when a reader goes out of range, and whether 2.4 GHz traffic on site will interfere. Plan for spare batteries on multi-shift operation, and test battery life at your real scan rate.
Match the handheld's scan engine to the code population. Standard-range models cover typical labels at arm's length, high-density models read small codes up close, and long-range models read rack labels at several metres. Check drop rating and sealing for the environment, and look for ESD-safe or disinfectant-ready housings in electronics or healthcare settings. Connectivity deserves attention: keyboard emulation is the quick way to reach a PC, whereas PLC connections may need a suitable base or adapter.
DPM handhelds are a separate class. They use dedicated illumination, often with a diffuser or stand-off and multiple lighting modes, together with a decoder built for low-contrast marks on metal or plastic. A standard handheld usually struggles on dot-peen and laser-etched marks. If you need DPM only occasionally, check whether one model can handle both DPM and labels at acceptable speed, and test with your own worst marks.
Code density and required resolution
The X-dimension is the width of the narrowest bar or the size of a module: 1 mil is 0.0254 mm, so 13 mil is 0.33 mm. Retail EAN/UPC at 100% magnification is 0.33 mm, while GS1 logistics labels are usually specified larger, at around 0.5 mm and up. Parts-level codes can be much smaller. Design for the smallest code you actually need to read, not the typical one, and respect quiet zones: typically at least 10X on many 1D symbologies and 1 module on Data Matrix.
For an imager, required pixels across = reading width / X-dimension x pixels per element. Use the same working rule as the 2D and DPM guide: about 2-3 px per narrow bar for 1D and 4-6 px per module for 2D. For a 600 mm belt and 0.33 mm bars, this gives 3,636-5,454 px across. A 4096 x 3000 (12 MP) area sensor gives 0.146 mm/px, or 2.25 px per bar, which is at the low end for 1D. A 2D code with 0.5 mm modules gets only about 3.4 px per module, under the 4-6 px rule, so a mixed code population would need a higher-resolution sensor, a narrower reading width or a larger code.
- High density (typically under about 0.2 mm): usually short-range station reading.
- Standard density (typically about 0.25-0.33 mm): general labels and retail-size codes.
- Low density (typically about 0.5 mm and up): logistics labels and longer-range reading.
- Plan on the worst pixel scale in the reading volume, which is usually the farthest distance.
Read-rate math with belt speed
For a laser, geometry decides how many attempts you get. In ladder orientation, the bars run along the direction of travel and the scan line crosses the belt, so the code passes through the line once: scans = scan rate x code height / belt speed. A code 15 mm tall at 2 m/s and 1,000 scans/s gets 15 / 2,000 x 1,000 = 7.5 scans. At 3 m/s that drops to 5, and since makers' formulas often subtract about 2 for partial scans at the code's edges, that leaves about 3 against a common minimum target of 5. In picket-fence orientation, the bars run across the direction of travel and the scan line runs along it: scans = scan rate x (scan width - code length) / belt speed. A 300 mm scan width and an 80 mm code at the same 2 m/s give (300 - 80) / 2,000 x 1,000 = 110 scans, which is far more attempts.
Skew is limited in both orientations, because without reconstruction a single straight scan line has to cross every bar. The maximum skew is approximately arctan(code height / code length). That 15 mm x 80 mm code tolerates about 10.6°, which loosely placed parcels can easily exceed.
For an imager, the code must be fully inside the field in enough frames: complete views = frame rate x (field along travel - code length) / belt speed. With the 12 MP sensor above, the field along travel is about 440 mm. A 100 mm code at 2 m/s stays fully inside for (440 - 100) / 2,000 = 170 ms, or about 5 frames at 30 fps. Dropping to 10 fps gives 1.7 frames, which no longer provides any margin. Aim for at least 2-3 complete views.
Then limit blur. The usual rule is to keep motion under half a module or bar during exposure. For 0.33 mm bars at 2 m/s, this means 0.165 mm / 2,000 mm/s = about 82 µs. For 1D codes, blur across the bars hurts and blur along them hurts much less, so orientation can buy some margin. On top of this, check decode time, because a slow decode with a short gap between items can miss the next one.
- Ladder laser: scans = scan rate x code height / belt speed.
- Picket-fence laser: scans = scan rate x (scan width - code length) / belt speed.
- Imager: complete views = frame rate x (field along travel - code length) / belt speed.
- Maximum exposure = half the X-dimension / belt speed.
- Line-scan line rate = belt speed / pixel size along travel.
Depth of field and autofocus
Parcel height is what makes logistics reading hard. Using a thin-lens approximation, depth of field is approximately 2 x N x c x (m + 1) / m², where N is the f-number, c is the acceptable blur and m is the magnification. For the 12 MP example with 3.45 µm pixels, m = 3.45 µm / 146 µm = 0.0236. At f/8 with a blur of about 2 px (7 µm), depth of field is about 200 mm. Stopping down to f/16 roughly doubles it, but costs a factor of 4 in light and adds diffraction blur. A parcel range of 0-800 mm cannot be covered by one fixed-focus setting at this density.
Geometry adds a second constraint. If the reader sits 1.8 m above the belt, then the top of an 800 mm parcel is at 1.0 m. A 600 mm field at belt level is only about 333 mm wide at that height, so a tall parcel near the belt edge can fall outside. Pixel scale is worst at the belt and field coverage is worst at the top of the tallest parcel, so check each at its own limit.
There are four standard answers. Stopping down and adding light works for small height ranges. Liquid-lens autofocus changes focus quickly, typically in milliseconds to tens of milliseconds, with no moving mechanical parts, and suits compact readers. Motorised focus works with larger optics at a slower rate and adds mechanical wear. In tunnels, an upstream height sensor or light curtain usually sets focus before the parcel arrives. Stacking two or three readers with overlapping focus bands is simple and adds redundancy.
Focus changes also set a minimum gap between parcels. A 30 ms focus change at 2.5 m/s uses 75 mm of belt travel, and a tall parcel followed closely by a low one is the case to test. If gaps can be smaller than this, the design needs a faster focus, extra readers or better singulation.
Conveyor and tunnel reading: line-scan, multi-side
On wide, fast belts with small codes, line-scan readers often beat area imagers, because the image is built continuously with no gaps or frame overlaps, and pixels across are plentiful. For a 1,000 mm reading width and an 8192 px sensor, the scale is 0.122 mm/px, which is 2.7 px on a 0.33 mm bar and 4.1 px on a 0.5 mm module. Square pixels at 2.5 m/s require 2,500 / 0.122 = about 20.5 kHz line rate, so exposure cannot exceed about 49 µs, which needs a powerful line light. The data rate is about 168 MB/s. An encoder keeps the scale correct if the belt speed varies. The encoder guide covers the details.
Multi-side coverage depends on where labels can appear. Top-only reading is enough when labels are placed consistently. Otherwise, add side readers, angled readers for leading and trailing faces, and a bottom reader looking through a gap between conveyor sections, for up to six-sided reading. The bottom gap must be small enough for short parcels to cross it safely, and it will collect dirt, so plan cleaning access. Each added face adds cost and commissioning effort, so sample your real label positions before specifying six sides.
A tunnel is a system rather than a set of readers. A controller combines reader results, associates each code with the right parcel using an entry photocell and an encoder for tracking, and sends one message per parcel to the WMS or sorter. Side-by-side parcels defeat most tracking, so singulation is usually a requirement. Parcels often carry several codes, so filter by format, length or prefix. A misread or wrong association is usually worse than a no-read, since a no-read can go to a manual lane whereas a mis-sort leaves the building. Check the decision deadline too: with a divert point 6 m downstream at 2.5 m/s, the result must arrive within 2.4 s.
- Entry photocell and encoder: define parcel position and the reading window.
- Height or dimension sensing: sets focus and supports association.
- Reader array: top, sides, front and back, bottom as required.
- Controller: fuses results and applies code filters and no-read handling.
- Exception lane: manual handling for no-reads, plus saved images for diagnosis.
Specifying and testing read rate
Translate percentages into exceptions per hour. At 3,000 parcels per hour, 99.5% means 15 no-reads per hour and 99.9% means 3. That number decides manual labour, so it is the figure that matters to the operation. Define it precisely before a trial: of the codes present and readable to a human, how many did the system read and assign correctly? Report damaged labels, missing labels and labels on an uncovered face separately, because they require different fixes.
Be careful with redundancy math. Two independent readers at 95% would combine to 1 - 0.05² = 99.75%, but real failures are correlated: a poorly printed or creased label tends to fail on every reader. Added readers help most with coverage and orientation, and less with poor print. If label quality limits the rate, the fix lies upstream. Regular checks with a verifier, using ISO/IEC 15416 for 1D and ISO/IEC 15415 for 2D, show whether print quality is drifting. A reader's built-in quality score is useful for trends but is not a formal grade.
Run the trial with the real label population at maximum speed, with minimum gaps, and at the tallest and lowest parcel heights, for long enough to count rare failures. Measuring a 99.9% target needs thousands of items, not a few dozen, so plan the sample size. Store images of every no-read: reviewing them is the fastest way to tell whether the cause is focus, blur, glare, position or print quality.
Read rate is best proven on your real labels and marks at line speed, not estimated from a symbology table. AIS Vision validates code reading applications and integrates tunnels and traceability stations with the rest of the line.
Frequently asked questions
Related categories
- 1D/2D readers
- Handheld industrial readers
- Logistics readers
- DPM readers
- Industrial code readers
Related guides
How to choose a 2D and DPM industrial code reader
A practical engineering guide to selecting image-based 1D, 2D and DPM code readers: how to match resolution and field of view to module size, set working distance and depth of field, pick DPM lighting and optics, and choose decode strategy, communication and grading.
Code verification and grading: ISO/IEC and GS1 for traceability
A practical guide to barcode and Data Matrix verification: how grading differs from reading, the ISO/IEC 15415 and 15416 parameters, ISO/IEC 29158 for direct part marks, GS1 application rules, and why pharma and medical packaging demand verified codes.
Encoder triggering for line scan cameras
Line scan geometry depends on encoder triggering: size line rate, PPR and dividers, choose the right outputs and control slip at the wheel.
Area scan vs line scan cameras
When to use a matrix (area scan) sensor versus a line sensor: discrete parts vs continuous web and cylindrical material, encoder sync, lighting and frame grabber needs.











