iRAYPLE R4013MG-12M — R4000 Series fixed-mount code reader; 1.3 MP (1280 × 1024) at 60 fps; 12 mm auto-focus lens; read distance 50–500 mm; integrated white/blue/red illumination; Ethernet, RS-232, PROFINET, EtherNet/IP, Digital I/O; IP65.
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
Scan technology
2D area imager (CMOS, global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR etc.; + DPM (MV-R4013MG-12M-WGG01E)
The 12 mm lens narrows the field to 64 × 51 mm at 150 mm, or 64 mm ÷ 1280 px = 0.050 mm per pixel, which suits smaller codes: 2 px per module corresponds to 0.10 mm (2 × 0.050 mm). Working distance remains 50–500 mm through motorised autofocus, and the integrated lighting comes in white, blue or red by order code, with diffused, polarized or non-polarized options.
DPM decoding and a 3 m/s maximum object speed are specified for the MV-R4013MG-12M-WGG01E order code, so confirm that code when direct-marked parts or fast lines are involved. The reader draws under 5 W from 9–26 V DC and decodes up to 60 codes/s using deep-learning code-reading algorithms with multi-parameter polling aimed at complex applications.
Best for
Small 2D marks with modules near 0.10 mm, read at 150 mm.
Direct-marked parts, using the order code that specifies DPM.
Machines that wire a hardware trigger and pass or fail signals directly, using 2 opto-isolated inputs and 3 opto-isolated outputs.
Selection notes
The field is only 64 × 51 mm at 150 mm; if parts wander, the R4013MG-07M offers 116 × 92 mm.
For longer reach or a wider range of distances, the R5016MG-12M reads at 80–1500 mm over GigE.
AIS Vision can validate DPM reads and lighting choice on your own parts before you fix the order code.
Specifications: General
Brand
iRAYPLE
Form factor
Fixed-mount
Reader type
Code reader
AI / deep learning
Built-in deep-learning based code reading algorithms and multi-parameters polling to ensure effects of complex applications
Specifications: Sensor
Resolution
1.3 MP (1280 × 1024)
Horizontal resolution
1280 px
Specifications: Performance
FPS
60 fps
Specifications: Interface
Communication
100M Ethernet; protocols: SDK,TCP Client,TCP Server,FTP,RS232,Profinet,Modbus,EtherNet/IP,MC(SLMP),FINS/UDP,FINS/TCP
Specifications: Optical
Field of view
64 × 51 mm (at WD 150 mm)
Focal length
12 mm
Focus
Motorised auto focus (M12 lens)
Integrated lighting
White (Diffused/2 Channel Non-polarized) · Blue (Diffused/Polarized/Non-polarized) · Red (Diffused/Polarized/Non-polarized) — depending on order code
Illumination colour
White (Diffused/2 Channel Non-polarized) · Blue (Diffused/Polarized/Non-polarized) · Red (Diffused/Polarized/Non-polarized) — depending on order code
Specifications: Electrical
Supply voltage
9–26V DC, 1.5A input
Power consumption
<5 W
Specifications: Environment
IP rating
IP65
Operating temperature
-20 °C to +50 °C
Specifications: Reading
Scan technology
2D area imager (CMOS, global shutter)
Supported codes
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR etc.; + DPM (MV-R4013MG-12M-WGG01E)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Supported codes ●
Integrated lighting ●
Illumination colour ●
order_option ●
Availability
white light, MV- order code Base
1D: code 128, code 39, code 93, EAN etc. and 2D: QR/Data Matrix/DPM etc.
White (Diffused/2 Channel Non-polarized)
White (Diffused/2 Channel Non-polarized)
Same configuration listed under the MV-R4013MG-12M-WGG01E order code
On request
blue light
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR etc.
Blue (Diffused/Polarized/Non-polarized)
Blue (Diffused/Polarized/Non-polarized)
—
On request
red light
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR etc.
Red (Diffused/Polarized/Non-polarized)
Red (Diffused/Polarized/Non-polarized)
—
On request
white light
1D: Code 39/Code 93/Code128/CodaBar/EAN8/EAN13/UPCA/UPCE/ITF25/2of5 (Industrial2of5)/standard25/GS1-128 etc. and 2D: Data Matrix/MQR/GS1 DM/GS1QR etc.
White (Diffused/2 Channel Non-polarized)
White (Diffused/2 Channel Non-polarized)
—
On request
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
DPM decoding is specified for MV-R4013MG-12M-WGG01E. Confirm it when ordering if your parts are direct-marked.
A 3 m/s maximum object speed is specified for the MV-R4013MG-12M-WGG01E order code. At 150 mm one pixel is 0.050 mm, which 3 m/s crosses in about 17 µs (0.050 mm ÷ 3000 mm/s), so the exposure has to be short.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE