iRAYPLE C01-10GE-RJ45-RJ45-FC — 10 Gigabit Ethernet cable (RJ45 to RJ45); End A RJ45 (with locking stud), End B RJ45; lengths 3–20 m (3, 5, 7, 10, 15, 20 m); structure (26AWG*1P+NW)*4C+NW+AB; Ø 6.8 mm; PVC jacket; min. bending radius 70 mm; drag-chain rated (10 million cycles); operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
10 Gigabit Ethernet cable (RJ45 to RJ45)
Cable length
3–20 m (3, 5, 7, 10, 15, 20 m)
Connector A
RJ45 (with locking stud)
Connector B
RJ45
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
Compatible with
10GigE industrial cameras (RJ45 with locking screws)
Flexing is the reason this version exists: 10 million drag-chain cycles on a 10GigE link. Compared with the static C01-10GE-RJ45-RJ45 it swaps four 23 AWG pairs for four 26 AWG pairs, trims the jacket from 7.8 mm to 6.8 mm and lowers the minimum bending radius from 75 mm to 70 mm. Finer conductors typically go with repeated flexing, and the thinner jacket takes less space in a chain.
The cable comes in 3, 5, 7, 10, 15 and 20 m. Anchor the cable at both ends of the chain, with the locking-stud End A on the camera, so the plugs never carry the load, and keep the chain's inner radius at or above 70 mm.
Best for
A 10GigE camera on a gantry or linear axis, with the cable running in an energy chain through every cycle.
A fixed 10GigE camera 16 to 20 m from the switch, since the static C01-10GE-RJ45-RJ45 stops at 15 m.
Pick-and-place or indexing axes that bend the cable on every move, where a cable not rated for flexing is not an option.
Selection notes
If nothing moves and 15 m is enough, the static version has the heavier 23 AWG pairs and also comes in 1 m.
The shortest length is 3 m, so a 1 m cabinet hop needs the static cable.
A camera at full 10 Gbit/s rate loads the switch uplink as well as the cable: when several cameras share an uplink, check it against their combined stream.
Specifications: General
Brand
iRAYPLE
Cable type
10 Gigabit Ethernet cable (RJ45 to RJ45)
Compatible with
10GigE industrial cameras (RJ45 with locking screws)
Specifications: Interface
Connector A
RJ45 (with locking stud)
Connector B
RJ45
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–20 m (3, 5, 7, 10, 15, 20 m)
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
26 AWG pairs instead of 23 AWG, a 6.8 mm jacket instead of 7.8 mm, a 70 mm minimum bending radius instead of 75 mm, 3–20 m instead of 1–15 m, and the 10 million cycle drag-chain rating.
No. Both versions have an RJ45 with locking stud on End A and a plain RJ45 on End B, rated for ≥750 mating cycles.