iRAYPLE 10GigE cable, RJ45 to RJ45, static — C01-10GE-RJ45-RJ45
C01-10GE-RJ45-RJ45
iRAYPLE C01-10GE-RJ45-RJ45 — 10 Gigabit Ethernet cable (RJ45 to RJ45); End A RJ45 (with locking stud), End B RJ45; lengths 1–15 m (1, 3, 5, 7, 10, 15 m); structure (23AWG*1P+AM)*4C+B; Ø 7.8 mm; PVC jacket; min. bending radius 75 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
10 Gigabit Ethernet cable (RJ45 to RJ45)
Cable length
1–15 m (1, 3, 5, 7, 10, 15 m)
Connector A
RJ45 (with locking stud)
Connector B
RJ45
High-flex / drag chain
No — static scenes
Compatible with
10GigE industrial cameras (RJ45 with locking screws)
This cable exists for cameras that have outgrown a Gigabit link. As an example, a 4096 × 3000 px, 8-bit camera at 60 fps produces 4096 × 3000 × 8 × 60 ≈ 5.9 Gbit/s of pixel data, almost six times what 1 Gbit/s GigE carries and within reach of a 10 Gbit/s link. It joins a 10GigE camera (RJ45 with locking screws) to a 10 Gbit/s switch or network card: End A has the locking stud for the camera, End B is a plain RJ45.
The build is for fixed wiring: four pairs of 23 AWG conductors, a 7.8 mm PVC jacket and a 75 mm minimum bending radius, so route it in a wide loop behind the camera and clamp it to the frame. Lengths are 1, 3, 5, 7, 10 and 15 m. The drag-chain -FC version uses 26 AWG pairs instead.
Best for
A 10GigE camera at a fixed station up to 15 m from the switch, where the cable is clamped once and never flexes.
A 1 m link between a camera and a switch mounted in the same machine frame; the drag-chain version starts at 3 m.
Upgrading a fixed station whose frame rate is capped by a Gigabit link, since the faster camera needs a 10 Gbit/s cable path to the switch.
Selection notes
If the camera or the cable moves, use C01-10GE-RJ45-RJ45-FC (3–20 m, 10 million cycles); this cable is rated for static installation only.
Every port in the path must run at 10 Gbit/s: one 1 Gbit/s switch port in the middle holds the camera to a tenth of the link rate. With several cameras, the switch uplink to the PC also has to carry their combined stream.
Beyond 15 m only the -FC version reaches 20 m; for longer runs put a switch nearer the camera or use a fibre link.
Specifications: General
Brand
iRAYPLE
Cable type
10 Gigabit Ethernet cable (RJ45 to RJ45)
Compatible with
10GigE industrial cameras (RJ45 with locking screws)
Specifications: Interface
Connector A
RJ45 (with locking stud)
Connector B
RJ45
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
1–15 m (1, 3, 5, 7, 10, 15 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
No. It is rated for static installation; C01-10GE-RJ45-RJ45-FC is the drag-chain version, with a 10 million cycle rating.
End A, the one with the locking stud, made for cameras with locking-screw RJ45 ports. End B is a plain RJ45 for the switch or network card.