IP ratings, housings and mounts for vision systems

IP codes define narrow tests, so learn what IP65, IP67 and IP69K cover and how to seal, cool and mount vision hardware for washdown and vibration.

What IP codes actually mean

The IP code, defined in IEC 60529, is an enclosure rating with two numerals. The first covers solid objects and dust, and the second covers water. An X in either position means that property was not rated, not that protection is zero: IPX7 makes no statement about dust. The tests are specific, and the details matter more than the numbers.

Two rules catch many buyers out. First, the numerals are not a ladder. Second numerals up to 6 are cumulative, but 7 and 8 are not. A product marked only IP67 has passed a still-water immersion test, not a jet test, unless it is dual-marked, such as IP65/IP67. IP69K is similarly separate, which is why devices intended for both conditions are marked IP67/IP69K.

Second, the code covers a narrow set of conditions: a new enclosure, clean water and a defined test duration. IEC 60529 does not address condensation, corrosive cleaners, UV, fungus, thermal cycling or seal ageing. It also says nothing about explosive atmospheres, which fall under separate ATEX and IECEx rules, or about impact, which has its own IK codes in IEC 62262 (IK08 is 5 J and IK10 is 20 J). NEMA types are not direct equivalents, because NEMA 250 also evaluates conditions such as corrosion and icing.

  • First numeral 5: dust-protected. Some dust may enter, but not enough to interfere with operation.
  • First numeral 6: dust-tight. No dust ingress in the test.
  • IPX5: water jets from a 6.3 mm nozzle at 12.5 L/min, from about 2.5 to 3 m.
  • IPX6: powerful jets from a 12.5 mm nozzle at 100 L/min, from about 2.5 to 3 m.
  • IPX7: temporary immersion, typically 1 m for 30 minutes.
  • IPX8: continuous immersion under conditions agreed with the manufacturer, more severe than IPX7. Always read the stated depth and time.
  • IP69K: hot, high-pressure jets of about 80 °C water at 8 to 10 MPa (80 to 100 bar) and 14 to 16 L/min, at close range from several angles. It comes from ISO 20653, which replaced DIN 40050-9. IEC 60529 has included a similar IPX9 test since a 2013 amendment.

Choosing the rating for your environment

Decide from the actual exposure. List what reaches the device, how often, at what pressure and temperature, and with what chemistry. Pick the rating that covers the worst routine condition, then protect separately against anything the rating does not cover. Bare industrial cameras are typically around IP30 to IP40, which is fine in a closed cabinet or a clean assembly cell and not much else.

Location can reduce the requirement. Moving the camera out of the direct spray zone, adding a splash shield or angling it so water runs off often achieves more than a higher rating. Conversely, check what cleaning staff actually do: a pressure lance held at 10 cm can defeat a device rated for hose jets at 3 m. Specify for real behaviour, not for the written procedure.

  • Dust with no water: IP5X or IP6X.
  • Oil mist, coolant splash or occasional hosing: IP65 or IP66, and check that the seals suit the coolant.
  • Risk of pooling or temporary flooding: IP67, alongside a jet rating if hosing also occurs.
  • Low-pressure washdown with detergents: IP66, or a dual marking such as IP65/IP67, with chemically resistant materials and a plan for pressure equalisation.
  • High-pressure, high-temperature cleaning: IP69K, combined with hygienic design in food, beverage and pharma.
  • Outdoors: add UV-resistant materials, condensation handling and an allowance for solar heating.

Housings, lens tubes and windows

There are three common routes to protection: a natively IP-rated camera with a lens tube, a protective housing around a standard camera, or a cabinet with a window. An IP-rated camera is compact and thermally simple, because the camera body is the enclosure and heat leaves directly through its walls and mount. A separate housing works with almost any camera but traps heat and adds interfaces to seal. Either way, the rating applies only to the assembly as tested, with its intended tube and mated connectors or caps.

Lens tubes need a length check. The internal length must clear the lens at its working focus position, plus any extension rings, filters and adapters, without touching the window. The internal diameter must clear the widest part of the lens, including locking screws. Set focus and aperture before closing, because most tubes give no access afterwards, and verify again once closed. External focus and iris feed-throughs exist, but each shaft is another seal to maintain.

The window is an optical element, so treat it as one. A flat window in front of the lens moves the focus plane away by about one-third of its thickness for glass (t x (1 - 1/n), with n about 1.5), so focus with the window fitted, especially in close-up and telecentric work. Each uncoated surface reflects about 4%. An anti-reflective coating reduces that loss and the ghosting it causes. A light mounted inside a housing reflects off the window into the lens unless it is baffled, so mount lights outside where you can.

  • Borosilicate or float glass: hard and scratch-resistant, good across visible and NIR. Food plants may restrict glass under their control rules, so check early.
  • Polycarbonate: shatter-resistant and often preferred where glass is restricted. It scratches easily, can craze with some cleaners, and is birefringent, which spoils polarised lighting setups.
  • Sapphire: very hard, for abrasive environments.
  • Fused silica: for UV work. Check transmission for any UV or SWIR application, since polycarbonate blocks most UV and ordinary glass blocks deep UV.
  • Make the window replaceable. Scratches, weld spatter and chemical attack turn it into a consumable. An air purge or air knife, using clean, dry, oil-free air, keeps it clear in mist and dust.

Cable glands and connector sealing

The cable entry is usually the lowest-rated point. A gland is rated only when clamped on a round cable within its specified diameter range, with its seal and locknut fitted correctly. An undersized cable, a flat cable or a jacket that cold-flows under compression loses the rating. So does a good gland on a poorly finished housing wall without its O-ring.

Pre-assembled camera cables do not fit through ordinary glands, because the connector is larger than the seal. The usual options are bulkhead connectors in the housing wall with a short internal patch, which also makes replacement easy; split glands or split grommets for terminated cables; or field-wireable connectors, which demand care at high speed and are best avoided at 10 Gbit/s. Multi-hole inserts handle several cables through one entry but seal only when every hole is filled, so use blanking plugs for spares. Inside the housing, check the bend radius: a straight connector plus the cable's minimum bend can typically need 50 to 80 mm behind the camera, which is why right-angle connectors are common.

Orientation and the cable itself matter. Bring cables up from below, or form a drip loop so water runs off before reaching the entry. Connectors are rated only when mated and torqued, so cap unused ports and check the rating of the mated pair. Water can also travel inside a cable: if the far end sits in a wet junction, moisture may wick along the core, and thermal cycling can pull it into the housing. Terminate at a dry point or with a sealed joint. Choose the jacket for the cleaners too: ordinary PVC can harden and crack, and ester-based PUR can degrade in hot, wet conditions, so use hydrolysis-resistant grades.

Washdown and hygienic design

Washdown has a failure mode that a rating test on a new device does not reveal: thermal pumping. A sealed housing that reaches 50 °C in production and is then hit by 15 °C water cools quickly, and the air inside contracts. In a rigid, perfectly sealed housing, pressure falls by about 11 kPa (101 kPa x (1 - 288/323)), about the same as a 1.1 m water column. The seal therefore sees roughly the pressure of an IP67 immersion test at every cleaning cycle, while being flooded with cleaner. Over months, seals give way, and first condensation and then water appears.

There are practical answers. Design the housing and seals to take that repeated stress, or equalise the pressure with a microporous membrane vent, which passes air and blocks liquid; choose one rated for your washdown level and place it out of direct jets. A positive-pressure dry-air purge is another option where clean air is available.

Even without leaks, sealed air carries moisture. Air closed up at 25 °C and 60% relative humidity has a dew point of about 17 °C, so the window fogs when it falls below that, which happens readily in a chilled food plant. Close housings in dry conditions, add desiccant and replace it whenever the housing is opened, or purge with dry air or nitrogen if the application justifies it. A cold window with warm electronics behind it is the worst case.

Cleaning chemistry attacks what IP tests do not. Alkaline foams attack anodised aluminium, chloride-based products can pit stainless steel if left to dwell, and every polymer and seal compound has incompatibilities. Use 316L stainless in aggressive areas and get compatibility data from the cleaning chemical supplier. Treat seals as wear items: inspect them when a housing is opened and replace them as recommended.

Hygienic design is a separate requirement from IP. An IP69K device can still harbour bacteria in threads, crevices or on horizontal ledges. Guidance comes from EHEDG, 3-A, EN 1672-2 and ISO 14159, which distinguish food, splash and non-food zones and call for smooth, drainable, cleanable surfaces.

  • Sloped surfaces with no ledges where water and soil can stand.
  • No exposed threads, open crevices or metal-to-metal seams; use hygienic seals and fasteners.
  • Round tube and stand-offs rather than T-slot profile in splash zones, with a clear gap for cleaning behind.
  • Smooth finishes, typically Ra 0.8 µm or better on product-contact surfaces.
  • Captive fasteners and no loose parts above exposed product, because of foreign-body risk.
  • Access for cleaning without removing the camera.

Thermal limits in a sealed housing

A sealed enclosure removes the airflow that normally carries heat away. Heat must cross from the camera to the internal air or bracket, then to the housing wall, then to the outside air. Cameras typically specify a maximum housing temperature, often somewhere in the 50 to 70 °C range, measured at a defined point on the body. That is not an ambient rating: the body runs above ambient by the sum of those steps.

Worked estimate: a cylindrical housing 70 mm in diameter and 200 mm long has about 0.05 m² of surface. In still air, combined natural convection and radiation is typically 5 to 10 W/m²K; take 8. Thermal resistance is then about 2.4 K/W, so a 6 W camera raises the wall about 15 K above ambient. In a 40 °C environment, the wall runs near 55 °C. If the camera sits on a plastic spacer in still internal air, its body can run another 10 to 20 K above the wall, landing at 65 to 75 °C, which is at or over many cameras' limits. Clamping the camera to the wall through a metal bracket and thermal pad can cut that second step to a few kelvin. This is an estimate, so confirm it on real hardware.

Temperature matters below the limit too. Dark current roughly doubles for every 6 to 10 K, so noise rises visibly in a hot camera. Thermal expansion shifts focus, so set focus after warm-up. Add every watt that shares the enclosure, including internal lights and media converters, plus solar gain outdoors. Camera power is usually highest at full frame rate. Many cameras report device temperature, so log it at full frame rate and worst-case ambient, after at least an hour of soak.

Lights have limits of their own. LED output falls as junction temperature rises, and overdrive limits usually assume a stated ambient. Keep controllers in a cabinet and only rated light heads in the washdown zone, and check the permitted cable length between controller and head.

  • Conduct heat out: a metal bracket and thermal pad from camera to wall or mounting structure.
  • Increase surface area: a larger or finned housing, with free air around it, or mounted to a metal frame.
  • Reduce the heat: lower frame rate, a smaller region of interest or a lower-power camera.
  • Add active cooling: forced air, vortex coolers on compressed air, or thermoelectric coolers.
  • Watch the dew point: cooling a surface below it replaces a heat problem with a condensation problem.

Vibration, mounting and adjustability

Vibration causes two separate problems: image movement and mechanical damage. Movement scales with working distance. A 0.02 degree angular wobble (0.35 mrad) at 500 mm moves the image about 0.17 mm at the object, or 1.7 pixels at 0.1 mm per pixel. A short exposure freezes it within a frame, but the frame-to-frame shift remains, and that hurts gauging and alignment.

Make mounts stiff, short and tied directly to the structure the part is referenced to. A useful estimate for natural frequency is 15.8 / sqrt(static deflection in mm) Hz: a bracket that sags 1 mm under the camera's weight resonates near 16 Hz, and one that sags 0.1 mm near 50 Hz. Keep that frequency well away from motor rotation, vibrating feeders and presses, and mount on a heavy frame member rather than a guard panel. Avoid long cantilevers: doubling the arm length increases tip deflection eightfold and lowers natural frequency by about 2.8 times.

Isolators help in narrower circumstances than expected. They reduce vibration only when the excitation frequency is above about 1.4 times the mount's natural frequency, and they amplify it near resonance. Use them against high-frequency machine vibration, not low-frequency sway.

For damage, read the datasheet's vibration and shock tests (IEC 60068-2-6 sine, 60068-2-64 random, 60068-2-27 shock) and compare them with the machine. A C-mount thread was not designed to carry a heavy lens under vibration, so support large lenses with a collar or bracket rather than hanging them from the camera. Lock focus and iris with set screws, and consider a ruggedised lens where vibration is routine. Use locking fasteners, clamp cables to the same body as the camera so a swinging cable does not load the connector, and observe the camera's stated thread depth, because an overlong screw can damage internals.

Adjustment is necessary for setup and a liability afterwards. Give the mount only the degrees of freedom you need, and make each one lockable. Ball heads and tripod adapters are fine on the bench but rarely hold position on a machine. Once set, lock it and apply a witness mark. Pin the camera plate so a replacement drops into the same position and avoids a full realignment. If product changes require moving the camera, use a slide with a scale, or a motorised axis, and store the position in the recipe.

If a station has to survive washdown or heat, plan the housings, cables and mounting together with the camera and lighting. AIS Vision designs and integrates complete stations for these environments.

  • Mount camera and light on the same rigid bracket when their geometry matters.
  • For line scan, align the sensor to the direction of travel and the light to the sensor line.
  • Leave room for cable bend radius, lens access and cleaning.
  • Keep the assembly out of forklift, operator and maintenance paths, or guard it.
  • Recheck calibration after any bracket adjustment.

Frequently asked questions

Related categories

  • Mounts and housings
  • Accessories
  • Machine vision lighting

Related guides

Recommended hardware

Mounts and housings

All mounts and housings →

Machine vision lighting

All machine vision lighting →
  • Basler Light Ring-100OD-White machine vision lighting
    BaslerBasler Standard Light Ring-100OD-WhiteLight Ring-100OD-White
    • Ring light
    • White (5000 K)
    • 67-101 mm
    • Continuous and strobe (internal LED controller, 2 operating modes)
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron / Sentech FLV-DB10181W machine vision lighting
    • Direct back light (backlight)
    • White LED
    • 73 x 73 mm
    • Yes - driven by Omron vision controller or FLV-TCC/FLV-ATC/3Z4S-LT IDGB strobe controller
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Lumher PD-5000K machine vision lighting
    LumherLumher PD White 5000KPD-5000K
    • Bar / linear (Linear series)
    • White 5000K
    • Continuous (1x) / Strobe (4x) (no strobe values listed for PD 13, PD 14, PD 15)
    • Semidiffuse 60° / Ultradiffuse 110°
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Request a technical quote

If you have a specific application, we help you select the right hardware and validate it.