FHV-VNB2 is the Ethernet lead of the FHV7, with a straight M12 connector at the camera, in 2, 3, 5, 10 and 20 m. Copper Ethernet links typically reach 100 m between devices, so even the 20 m cable stays well inside that: the limit is machine layout and cable handling, not the signal.
Confirm the connector on the far end with us, so that it suits your switch or PLC port. Over long parallel runs, keep this cable out of the same bundle as the Power / I/O lead (FHV-VDB2), because switching loads on I/O lines can couple noise into data lines. The standard version carries no flex rating: for a camera that moves, use the super bend resistant FHV-VNBX2 (5 m) instead.
Best for
Fixed FHV7 stations linked to a switch in the same or a nearby cabinet, with five lengths from 2 to 20 m to match the route.
Multi-camera lines where each FHV7 gets its own leg to a central switch; the five lengths let you trim slack station by station.
Cameras with free depth behind the connector, so the straight plug needs no extra clearance work.
Selection notes
A straight exit needs clearance behind the FHV7. If the camera is close to a wall or panel, FHV-VNLB2 offers the same five lengths with a right-angle connector.
Fixed installations only: moving cameras need FHV-VNBX2 (5 m) or FHV-VNLBX2 (5 or 10 m).
Order the length you need rather than joining shorter leads with couplers; each extra connector is another point where the link can fail.
Specifications: General
Brand
Omron
Cable type
Ethernet cable
Compatible with
FHV7 (listed on Omron's FHV7 model pages; description: "FHV7")
Specifications: Interface
Connector A
M12
Connection
M12 connector
Specifications: Mechanical
Cable length
2 / 3 / 5 / 10 / 20 m
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Cable length ●
Availability
FHV7 Ethernet cable, straight 2 m, M12 connector Base
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
It is the network lead. The FHV7 has a separate Power / I/O connection with its own cable, FHV-VDB2 and its variants, so order that as well.
Choose straight (this cable) when there is free space behind the camera, and FHV-VNLB2 when the connector must turn immediately.