Basler Cable GigE, Cat 6, M12/RJ45, DrC — GigE data cable, M12 8-pin, X-coded, male (camera side), to RJ-45, click-lock (host side), drag-chain rated, 5 lengths 5–25 m. The twisted and shielded cable ensures stable data transmission from Basler GigE and 5GigE cameras, even in drag chain applications and under demanding environmental conditions with dust and water.
This is the drag-chain cable for M12 GigE cameras: an M12 8-pin X-coded male plug at the camera, RJ-45 click-lock at the host, five lengths from 5 to 25 m (5, 10, 15, 20, 25 m), Premium line with a 36-month warranty. Basler describes the twisted, shielded cable as stable on GigE and 5GigE cameras, including in drag chains and in environments with dust and water. The compatible camera is the Basler ace 2.
The static X-coded cable Basler Cable GigE M12, M, 8P/RJ45 is offered in 2 m and 10 m only, so for an X-coded M12 run between 10 and 25 m this is the Basler option, in a chain or fixed. Any camera that moves needs a drag-chain cable like this one. Ask us for the bending-cycle rating before sizing a long-stroke chain. X-coded M12 will not mate with an A-coded socket, so check the camera's socket first.
Best for
An ace 2 on a gantry or linear axis, 10 to 25 m from the control cabinet, with the cable guided in a drag chain.
Machines with dust or water around the camera, where a screwed M12 connection is typically more secure than a latch.
Multigigabit set-ups with 5GigE cameras, since Basler describes this cable as suitable for both GigE and 5GigE cameras.
Fixed runs of 15 to 25 m to an ace 2, where the static X-coded M12 cable stops at 10 m.
Selection notes
If the camera does not move, the static M12 cable at 2 or 10 m is the simpler choice for short runs.
Pick the length from the whole route, adding the travel of the chain; 25 m is the maximum available.
Confirm that the camera has an M12 X-coded socket; the compatible camera is the ace 2.
The host end is a click-lock RJ-45, so keep that end in the cabinet, away from the moving section.
Specifications: General
Brand
Basler
Cable type
GigE (Ethernet) — Basler interface "GigE"
Compatible with
Area Scan Cameras: Basler ace 2
Specifications: Interface
Connector A
M12 8-pin, X-coded, male (camera side)
Connector B
RJ-45, click-lock (host side)
Connection
M12 (M12 8-pin, X-coded, male)
Specifications: Mechanical
Cable length
5–25 m (5, 10, 15, 20, 25 m)
High-flex / drag chain
Yes — drag-chain rated (Basler: "drag chain")
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Basler names the ace 2.
It is drag-chain rated and available up to 25 m, while the static X-coded cable is offered in 2 m and 10 m.