X-coded M12 on the camera side, RJ-45 click-lock at the host, in 2 m or 10 m, for static installation. X-coded M12 is built for multigigabit speeds (typically up to 10 Gbit/s) and is keyed so that it will not mate with an A-coded socket, the type used by Basler Cable GigE, M12 A 8P Plug, RJ45.
The host cards named for this cable are the Basler 5GigE Interface Card, 4 Port, the 5GigE Interface Card, 4 Port PoE+ and the 2.5GigE Interface Card, 4-CH PoE+, all multigigabit. As an example, a 5 MP, 8-bit stream at 100 fps = 5 000 000 × 8 × 100 = 4 Gbit/s = 500 MB/s, which needs 5GigE (5 Gbit/s ≈ 625 MB/s raw) rather than 1GigE (125 MB/s raw) or 2.5GigE (312 MB/s raw).
Best for
Multigigabit cameras on a vibrating machine frame, where a screwed M12 coupling holds better than a latch.
PoE+ powered cameras on the 4-port 5GigE PoE+ card, where the camera supports it and one cable carries both data and power.
Systems that need a rugged camera end but a standard RJ-45 at the PC or switch.
Selection notes
The camera must have an M12 X-coded socket; an A-coded socket will not accept this plug.
The cable is static. For a moving camera, Basler Cable GigE, Cat 6, M12/RJ45, DrC covers 5–25 m in a drag chain.
Lengths are 2 m and 10 m only, so plan the routing for one of the two.
Compatible hosts are multigigabit cards; confirm the camera model and its link speed with us.
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
X-coded is designed for higher speeds and has a different keying, so it does not mate with an A-coded socket. This cable is X-coded.
Basler 5GigE Interface Card 4 Port, 5GigE Interface Card 4 Port PoE+ and 2.5GigE Interface Card 4-CH PoE+.