iRAYPLE GigE cable, M12 8pin A-code male to RJ45, static — CABNET-M12A8-RJ45
CABNET-M12A8-RJ45
iRAYPLE CABNET-M12A8-RJ45 — Gigabit Ethernet cable (M12 to RJ45); End A M12 8pin A-code Male, End B RJ45; lengths 2–25 m (2, 5, 10, 15, 20, 25 m); structure 24AWG*4P+AEB; Ø 6.5 mm; PVC jacket; min. bending radius 70 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
Gigabit Ethernet cable (M12 to RJ45)
Cable length
2–25 m (2, 5, 10, 15, 20, 25 m)
Connector A
M12 8pin A-code Male
Connector B
RJ45
High-flex / drag chain
No — static scenes
Compatible with
GigE industrial cameras (M12 8-pin A-coded camera connector)
Gigabit Ethernet over copper uses all four pairs, and the 24AWG*4P structure supplies four pairs for the eight pins of the M12 A-coded plug, with an RJ45 at the other end for the switch or network card. The camera socket has to be A-coded: an X-coded M12 connector is keyed differently and will not mate with it, so check which type your camera has.
Keep bends above the 70 mm minimum radius, about 11 times the 6.5 mm jacket diameter (70 ÷ 6.5 ≈ 10.8), which needs space behind the camera connector and where the cable enters the cabinet.
Best for
Fixed GigE cameras with an M12 8-pin A-coded connector on a frame or post, where the cable is clamped and never flexes.
Longer fixed runs of 15, 20 or 25 m to a remote cabinet, leaving room in the 100 m channel for a patch panel.
Test benches and commissioning, where a 2 m or 5 m lead links the camera to a laptop or a switch.
Selection notes
For a camera that moves, take CABNET-M12A8-RJ45-D (5, 10 or 15 m, 10 million drag-chain cycles); this cable is for static scenes.
This lead is rated to 30 VDC, below the typical 44–57 V of IEEE 802.3af/at PoE, so do not plan to run PoE through it without confirming with us.
For runs beyond 25 m, put a switch near the machine and keep the whole channel inside the typical 100 m limit.
Specifications: General
Brand
iRAYPLE
Cable type
Gigabit Ethernet cable (M12 to RJ45)
Compatible with
GigE industrial cameras (M12 8-pin A-coded camera connector)
Specifications: Interface
Connector A
M12 8pin A-code Male
Connector B
RJ45
Connection
M12 (camera end: M12 8pin A-code Male)
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
2–25 m (2, 5, 10, 15, 20, 25 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
GigE industrial cameras with an M12 8-pin A-coded connector. The RJ45 end plugs into a switch or network card.
This cable reaches 25 m. Gigabit copper links typically allow 100 m for the whole channel including patch cords, so a fixed run behind it can add the rest.