iRAYPLE GigE cable, M12 8pin A-code male to RJ45, high-flex (drag chain) — CABNET-M12A8-RJ45-D
CABNET-M12A8-RJ45-D
iRAYPLE CABNET-M12A8-RJ45-D — Gigabit Ethernet cable (M12 to RJ45); End A M12 8pin A-code Male, End B RJ45; lengths 5–15 m (5, 10, 15 m); structure 24AWG*4P+AEB; Ø 7.2 mm; PVC jacket; min. bending radius 70 mm; drag-chain rated (10 million cycles); operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
Gigabit Ethernet cable (M12 to RJ45)
Cable length
5–15 m (5, 10, 15 m)
Connector A
M12 8pin A-code Male
Connector B
RJ45
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
Compatible with
GigE industrial cameras (M12 8-pin A-coded camera connector)
This is the moving-camera version of CABNET-M12A8-RJ45: rated for 10 million drag-chain cycles and offered in 5, 10 and 15 m. The jacket is thicker, Ø 7.2 mm against 6.5 mm, so check it against the chain's inner height. The 70 mm minimum bending radius is unchanged, about 9.7 times the diameter here (70 ÷ 7.2), so the chain's bend radius should be 70 mm or more.
Wear on a flexing Ethernet cable often shows up gradually. Gigabit uses four pairs while 100 Mbit/s uses two, so when one of the extra pairs breaks the link can renegotiate to 100 Mbit/s instead of dropping out, and a camera streaming more than that starts to lose frames. Check the negotiated link speed during maintenance and replace the cable before it fails completely.
Best for
Cameras on gantries or slides that follow a drag chain and need a GigE link with an M12 8-pin A-coded plug.
Replacing a static CABNET-M12A8-RJ45 that fatigued on a moving axis: the connectors are the same and this one is built for the motion.
Chain runs of 5, 10 or 15 m on machines whose cabling to the switch continues as a separate static run.
Selection notes
Moving cable stops at 15 m. If the switch is farther, bring it closer to the machine and continue with fixed Ethernet from there, keeping the whole channel inside the typical 100 m.
The cable is rated to 30 VDC, below the typical 44–57 V of IEEE 802.3af/at PoE, so confirm with us before powering a camera through it.
Only drag-chain bending is rated. A camera that rotates or rides on a robot wrist also twists the cable, which the rating does not cover.
Specifications: General
Brand
iRAYPLE
Cable type
Gigabit Ethernet cable (M12 to RJ45)
Compatible with
GigE industrial cameras (M12 8-pin A-coded camera connector)
Specifications: Interface
Connector A
M12 8pin A-code Male
Connector B
RJ45
Connection
M12 (camera end: M12 8pin A-code Male)
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
5–15 m (5, 10, 15 m)
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
A thicker Ø 7.2 mm jacket, the 10 million cycle chain rating and a 5 to 15 m length list. The 70 mm bending radius and the connectors are the same.
Watch the link speed the camera negotiates: a drop from 1 Gbit/s to 100 Mbit/s is a typical sign that a pair is failing.