Basler BL Camera Mount 45 — lighting mount / bracket. Illumination holder for the combination of Basler Camera and Basler Standard Light allow the construction of very compact units without additional design effort.
This mount carries the Flatdome-200x200 and Flatdome-200x300 as well as the small Light Ring-70OD, so one bracket covers two very different lighting techniques on an ace, ace 2 or MED ace camera: a compact ring light and a large diffuse dome.
The Ring-70OD is a close-in light that surrounds the lens and lights flat, matt surfaces evenly, though a glossy surface reflects it back as a bright ring. A 200x300 dome is the opposite choice: its wide, soft light typically keeps hot spots down on larger or shinier parts. Both ride on the camera, so the weight of a big dome sits at the front of the head, and the bracket behind it has to be stiff enough to hold the aim still.
Best for
Larger parts that need a big diffuse lit area, using the 200x200 or 200x300 Flatdome to cover the field evenly.
Small, flat or matt features lit with the compact Ring-70OD, where the head must stay small.
Textured shiny surfaces, where the soft light of the large dome keeps hot spots out of the image.
Selection notes
For the smaller Flatdomes (50x100, 100x100, 100x200) choose the BL Camera Mount 36; this mount is matched to the larger two.
The big domes make the head front-heavy. Support the assembly at the mount and keep cables from pulling on it.
The light rides on the camera, so the working distance of your lens also sets how far the ring or dome sits from the part. Check that this distance suits the light before you order.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
The Basler Light Ring-70OD, Light Flatdome-200x200 and Light Flatdome-200x300.
No. The 50x100, 100x100 and 100x200 domes belong to the BL Camera Mount 36.