A flat flex cable with a ZIF connector at each end, in 0.05 m, 0.15 m and 0.3 m for the dart. These lengths are board-level: the cable spans a short gap inside an enclosure, not a run to a cabinet.
Flat flex cables are less forgiving than round cables. A ZIF latch typically survives only a limited number of mating cycles, and the cable should be bent once at a gentle radius rather than flexed repeatedly. Flat cables are also made with contacts on the same face or on opposite faces at the two ends, so confirm the orientation your boards need and ask us if in doubt.
Best for
dart M builds where the camera-side and host-side ZIF connectors are 0.05 to 0.3 m apart and a flat cable fits the gap.
Embedded prototypes where board spacing changes between revisions, since three lengths cover tighter and looser layouts.
Fixed internal connections that are assembled once and not unplugged during service, which suits a ZIF latch with limited mating cycles.
Selection notes
Measure the connector-to-connector path including the bend, and take the shortest length that leaves a little slack; a longer flat cable is harder to route cleanly inside a housing.
It is for static use; repeated flexing is the usual way flat cables fail.
Open the ZIF latch before inserting and close it afterwards; forcing the cable damages the contacts.
Specifications: General
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable"
Compatible with
Area Scan Cameras: Basler dart
Specifications: Interface
Connector A
ZIF (camera side)
Connector B
ZIF (host side)
Specifications: Mechanical
Cable length
0.05–0.3 m (0.05, 0.15, 0.3 m)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
No. It has a ZIF connector at both ends, so it joins two boards. For I/O and power wiring to your own terminals, use the dart M I/O Cable, IDC/open (0.5 m).
The options are 0.05 m, 0.15 m and 0.3 m. Choose by the routed distance between the two connectors, not the straight-line gap.