Basler IP-Housing Lens Tube 60mm — IP67 lens housing (lens tube), size 60 mm x 55 mm x 55 mm, weight 57 g, material Glass filled nylon, high impact, lens Ø up to 47 mm, operating 0 °C - 50 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M50 adapter ring is required (article number: 2200002586). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), no adapter ring is required. However, for complete protection of the camera, a suitable cable gland is also required. Only the combination of camera housing, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
60 mm x 55 mm x 55 mm
Weight
57 g
Housing material
Glass filled nylon, high impact
Operating temperature
0 °C - 50 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-0816-2M f8mm, Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1620-5M f16mm, Basler Lens C23-5028-5M f50mm, Basler Lens C23-3520-5M f35mm, Basler Lens C23-7538-16M f75mm, Basler Lens C125-2522-5M f25mm +10 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M50 Adapter Ring
Eighteen Basler lenses are compatible with the 60 mm tube, more than with the 50 mm (15) or 70 mm (16) tube, and they include f8, f12, f50 and f75 types. If your lens is among them, this is the tube that covers the widest span of focal lengths.
A short focal length such as the f8 lens looks through the window at a wide angle, so the window and tube must not cut into the field; stay with the compatible lenses rather than assuming any lens of that focal length will do. The window is BK7 glass with an anti-reflective coating, and since it sits close to the lens, dirt or film on it typically reduces contrast across the whole image, so plan for cleaning access.
Best for
Stations that need an f8 wide-angle lens or an f75 long lens behind a sealed window: both types are among the 18 compatible lenses.
Stations where the lens must be protected from dust or spray and no more than 60 mm of tube length can be accepted.
Plants running several different Basler lenses that want to standardise on one tube length for as many of them as possible.
Selection notes
For a lens that is not among the 18, try the 70 or 80 mm tube or the Medium 100mm tube; compare the exact lens model, not just its focal length.
The mount depends on the camera: an ace 2 IP67 camera takes the M28 to M50 adapter ring (article number 2200002586), while the separate camera housings for ace Classic, ace U, ace 2 and racer 2 S need no ring.
IP67 is reached only with camera housing, this tube and a cable gland together.
Wipe the window with a lens-safe method; scratching the anti-reflective coating costs light and adds flare.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-0816-2M f8mm, Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1620-5M f16mm, Basler Lens C23-5028-5M f50mm, Basler Lens C23-3520-5M f35mm, Basler Lens C23-7538-16M f75mm, Basler Lens C125-2522-5M f25mm +10 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M50 Adapter Ring
Specifications: Environment
Operating temperature
0 °C - 50 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Eighteen Basler lenses are compatible, including f8, f12, f16, f25, f35, f50 and f75 types.