Basler Opto-I/O Cable, HRS 6p/open, P — I/O / power cable, Hirose 6-pin (HR10A-7P-6S) (camera side), to none (open end) (host side), static installation, length 10 m. The twisted cable has a Hirose 6-pin connector on the camera side. The other end is open so that the cable can be shortened to match individual requirements.
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Opto-coupled means the camera's inputs and outputs are separated from its electronics by an optocoupler. A ground offset or noise spike on the PLC side is then largely kept out of the camera, which is why opto lines are the usual choice for signals from cabinets, sensors and controllers over long, noisy runs. This 10 m cable brings those lines out of the Hirose 6-pin connector of ace USB 3.0 and GigE cameras, ready to be terminated at the PLC or sensor.
The cable is twisted, Premium line, for static installation, with an open far end that you can shorten and terminate on the PLC or sensor side. It serves the opto-coupled lines; GP-I/O Cable, HRS 6p/open, P (10 m) serves the direct-coupled ones, and the Opto-GP-I/O Y Cable (2 × 10 m) serves both groups.
Best for
Triggering an ace from a PLC output in a control cabinet with a different ground reference.
Photoelectric sensors and encoders that sit meters away from the camera, with the isolation absorbing ground differences.
Cells with mixed power domains, where the camera should not share a ground with the signal source.
Selection notes
Check the voltage range and polarity of the opto inputs in the camera manual against your source, for example a PNP or NPN output.
Shorten the open end to the run you need rather than leaving a coil of surplus cable beside power wiring.
Use the GP-I/O cable instead if the signals are logic-level and local to the camera.
Specifications: General
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Compatible with
Area Scan Cameras: Basler ace, Basler MED ace
Specifications: Interface
Connector A
Hirose 6-pin (HR10A-7P-6S) (camera side)
Connector B
none (open end) (host side)
Specifications: Mechanical
Cable length
10 m
High-flex / drag chain
No — static installation (Basler: "static")
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
An optocoupler isolates the camera from the signal source, so ground differences and noise on the PLC side are not passed straight into the camera.
Yes. It is for the opto-coupled I/Os of ace USB 3.0 and GigE cameras, and the MED ace is compatible too.