Basler Power-I/O Cable M5 4p/open — I/O / power cable, M5 4-pin (camera side), to none (open end) (host side), static installation, length 10 m. The twisted cable has a M5 4-pin connector on the camera side. The other end is open so that the cable can be shortened to match individual requirements. Not recommended for control of GPIOs of the Basler ace camera.
Built for ace Camera Link cameras, this cable brings power and a trigger signal to the camera through a small M5 4-pin connector. The cable is twisted, which typically helps a trigger line reject noise picked up along a 10 m run. The far end is open, so it is cut to length and wired to your supply and trigger source.
Basler does not recommend it for controlling the GPIOs of the ace camera, so treat it as a power-and-trigger lead and not a general I/O harness. It is for static installation, and M5 is a small connector, so clamp the cable close to the camera instead of letting 10 m of cable hang on the plug.
Best for
ace Camera Link cameras triggered by a machine signal, such as a photoelectric sensor or PLC output, that you wire directly to the camera.
Replacing a failed power-and-trigger lead on an existing ace Camera Link station.
Cabinet-to-camera runs of up to 10 m on a fixed frame, trimmed to the route.
Selection notes
Check that the camera has an M5 4-pin port. ace 2 cameras use M8 6-pin cables, for example the Power-I/O Cable, M8 6p/open, P (5 m or 10 m).
Typical PLC outputs switch 24 V, so check the camera's trigger-input voltage range before wiring one to this cable.
Camera Link also needs a frame grabber on the host side, which this cable does not replace.
Specifications: General
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable"
Compatible with
Area Scan Cameras: Basler ace
Specifications: Interface
Connector A
M5 4-pin (camera side)
Connector B
none (open end) (host side)
Specifications: Mechanical
Cable length
10 m
High-flex / drag chain
No — static installation (Basler: "static")
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
It is made for the ace Camera Link family. ace 2 cameras use M8 6-pin connectors, so they take a different cable, such as the Power-I/O Cable, M8 6p/open, P.
Basler does not recommend that. The cable is intended for power supply and trigger.