Basler Power-I/O PLC+ Cable, HRS 6p/open, P (10 m)
Power-I/O PLC+ Cable, HRS 6p/open, P
Basler Power-I/O PLC+ Cable, HRS 6p/open, P — I/O / power cable, Hirose 6-pin (HR10A-7P-6S) (camera side), to none (open end) (host side), static installation, length 10 m. The twisted cable has a Hirose 6-pin jack on the camera side. The other end is open so that the cable can be shortened to match individual requirements. FEATURES Camera Input: Alignment of signal level for logical 0 from PLC (<8.4V) to TTL (<1.4V) Camera Input, Output and Power Supply: Reverse voltage protection Secured against power-on overvoltage peaks Secured against positive/negative overvoltage peaks Improved EMC safety
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
A PLC and a camera input do not share logic levels, and this cable is built to bridge them. It aligns the PLC's logical 0 (below 8.4 V) with the camera's TTL logical 0 (below 1.4 V). For example, a PLC output sitting at 8 V is still a valid logical 0 for the PLC, yet it is far above the 1.4 V TTL low limit and would not read as a 0 at a TTL input; the cable aligns that difference.
Protection is the second reason to choose it. It adds reverse-voltage protection on the camera input, output and power supply, protection against power-on overvoltage peaks and against positive and negative overvoltage peaks, and improved EMC safety; the 10 m Premium cable is EMC-shielded. These matter on cabinet wiring shared with contactors and drives, where a miswire or switching spike would otherwise reach the camera.
Best for
ace GigE cameras on PLC-controlled lines, where the trigger arrives from a PLC output.
Cabinets with contactors and drives, where switching spikes and overvoltage peaks are routine.
Commissioning on site with several trades touching the wiring, where a reversed supply wire is a realistic risk.
Selection notes
The Hirose 6-pin ace and MED ace are covered; the ace 2 uses an M8 connector and needs a different lead.
If the trigger already works at TTL level, the Power-I/O Cable, HRS 6p/open, twisted, P (5 m or 10 m) is the plain alternative.
Basler describes it for ace GigE cameras; ace Camera Link cameras use the M5 4-pin Power-I/O Cable M5 4p/open (10 m).
Only 10 m is offered, with an open end for static installation, so measure the route before cutting.
Specifications: General
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Compatible with
Area Scan Cameras: Basler ace, Basler MED ace
Specifications: Interface
Connector A
Hirose 6-pin (HR10A-7P-6S) (camera side)
Connector B
none (open end) (host side)
Specifications: Mechanical
Cable length
10 m
High-flex / drag chain
No — static installation (Basler: "static")
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Yes. Basler specifies reverse-voltage protection on the camera input, output and power supply.
This one is built to bridge the levels: it aligns the PLC's logical 0 (below 8.4 V) with the TTL level (below 1.4 V), and it adds the protection circuits above.