iRAYPLE 6-pin power & I/O cable, 6-pin female to open end, static — C02/C03-IO-6PIN
C02/C03-IO-6PIN
iRAYPLE C02/C03-IO-6PIN — 6Pin Power&I/O Static Cable; End A 6-pin, Female, End B Open; lengths 0.6–15 m (0.6, 1, 3, 5, 7, 10, 15 m); structure 26AWG*(2P+2C)+AB; Ø 5.2 mm; PVC jacket; min. bending radius 55 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Cable length
0.6–15 m (0.6, 1, 3, 5, 7, 10, 15 m)
Connector A
6-pin, Female
Connector B
Open
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Short lengths set this static 6-pin lead apart: besides 3, 5, 7, 10 and 15 m it comes in 0.6 m and 1 m, short enough for a pigtail between a camera and a terminal block in the same enclosure. All lengths use one 26 AWG construction, two pairs plus two single conductors, in a 5.2 mm PVC jacket with a 55 mm minimum bending radius.
The cable powers the camera and carries its I/O wiring to an open end. Supply voltage drops with length: for an example 0.3 A load through one 26 AWG conductor (typically about 0.134 Ω/m) and back, 15 m drops 2 × 15 m × 0.134 Ω/m × 0.3 A ≈ 1.2 V, while 0.6 m drops almost nothing, so check the camera's minimum supply on the longest runs. End B is a plain open end, without the DC5.5 jack of C02-IO-6PIN-DC-LC.
Best for
A 0.6 m or 1 m pigtail between a 6-pin camera and a terminal block inside the same enclosure.
Fixed 6-pin camera wiring from 3 to 15 m where the PVC jacket is enough and no chain is involved.
Bench rigs where a camera is unplugged and re-plugged often, since the connector is rated for ≥750 mating cycles.
Selection notes
For a barrel-plug supply choose C02-IO-6PIN-DC-LC (static, 3–15 m) or C02-IO-6PIN-DC-FC (drag chain).
This cable is not for chains: C02/C03-IO-6PIN-FC covers moving use from 1 to 30 m.
Wire the open end from the camera's pin table, and keep the supply within the cable's 30 VDC maximum.
Specifications: General
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
6-pin, Female
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
0.6–15 m (0.6, 1, 3, 5, 7, 10, 15 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
End B is a plain open end here, while C02-IO-6PIN-DC-LC adds a DC5.5 female jack. Conductors, jacket and bending radius are the same; this one also comes in 0.6 m and 1 m, and the DC-jack version does not.
Yes: 26 AWG with two pairs and two single conductors at 5.2 mm. Unlike the drag-chain version, no length uses a heavier pair.