Basler Camera housing ace 2 GigE — IP67 camera housing, size 95.9 mm x 55 mm x 55 mm, weight 357 g, material Type 2 anodised aluminium, lens Ø up to 47 mm, operating 0 °C - 50 °C, IP67. Note: Camera housing, lens housing, and cable gland are required for complete protection of the camera and lens.
Brand
Basler
Dimensions
95.9 mm x 55 mm x 55 mm
Weight
357 g
Housing material
Type 2 anodised aluminium
Operating temperature
0 °C - 50 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
This housing is for ace 2 GigE cameras, and it is also compatible with Basler UV and SWIR cameras and with the racer 2 line scan camera. The 95.9 mm × 55 mm × 55 mm body is Type 2 anodised aluminium with an EPDM seal, takes lenses up to 47 mm in diameter and is specified for 0 °C to 50 °C.
IP67 is a property of the assembled system, not of the housing alone: it is reached only with the camera housing, a lens housing (lens tube) and a cable gland together, so budget for all three. The sealed head is the 95.9 mm body plus the tube length, for example 95.9 + 60 = 155.9 mm with a 60 mm tube. The aluminium body helps carry heat away from the camera, but a sealed enclosure limits air movement, so check the camera's own temperature limit at your ambient.
Best for
ace 2 GigE cameras on wet or dusty lines, where Ethernet cabling, which typically reaches 100 m on copper, lets the camera sit far from the cabinet.
UV cameras needing an IP67 enclosure: of the two ace 2 housings, this is the one with UV compatibility, and SWIR cameras are compatible too.
Plants running ace 2 GigE, SWIR or UV and racer 2 line scan cameras that want one housing type to stock for all of them.
Selection notes
Order the IP67 set as three parts: this housing, a lens tube and an M25 cable gland in single hole, double hole or drillable form.
For ace 2 cameras with USB, CXP or GMSL interfaces choose the Camera housing ace 2 USB / CXP / GMSL; for the ace GigE the Camera housing ace GigE is the match.
For UV imaging, the IP-Housing Lens Tubes use BK7 windows, which typically transmit poorly in the deep UV, so confirm window transmission in your band before specifying a tube.
Match the gland to the cable jacket, and use the double-hole version only when two cables really leave the housing.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
No. Basler gives IP67 for camera housing, lens housing and cable gland together. Without the lens tube or the gland the enclosure is open.
357 g for the housing alone, without camera, lens or gland.