Skip to content
Technical guide12 min read

SWIR, UV and thermal imaging for machine vision

Learn what SWIR, UV and LWIR thermal cameras reveal that visible light cannot, and how sensors, optics, lighting, cooling and cost change the design.

Start with the contrast you need

Choosing a non-visible band is a physics question: which wavelength makes the feature differ from its background? Standard silicon cameras cover roughly 350 to 1000 nm, with response falling steeply above about 900 nm and effectively ending near 1100 nm. Try the cheap option first. Near-infrared lighting around 850 or 940 nm with a silicon camera already makes many dyes and inks fade, and it uses standard lenses and cameras. If that gives the contrast you need, you do not need the more expensive bands.

If it does not, the feature usually points to the band. A quick way to confirm is a spectrometer reading of good and bad samples, or a test with a few filtered wavelengths. Measuring the actual material removes most of the guesswork, because coatings, pigments and moisture levels rarely behave exactly like published curves.

  • Water content, seeing through silicon or some plastics and inks, materials identical in visible light: SWIR.
  • Adhesives, inks, oils or coatings that fluoresce: UV excitation with a visible camera and a blocking filter.
  • Fine scratches and surface-only contrast on polished parts, UV-absorbing films: reflected UV with a UV-capable camera.
  • Temperature, heat flow, seal quality and thermal anomalies near ambient: LWIR thermal.
  • Very hot processes above a few hundred °C: SWIR or MWIR may outperform LWIR, because emission shifts towards shorter wavelengths as temperature rises and the short-wave signal changes faster with temperature.

What SWIR reveals

Short-wave infrared is usually taken as about 900 to 1700 nm in machine vision, which is the range of standard InGaAs detectors, although some definitions extend to about 2500 nm. Images look much like visible monochrome images, because the camera sees reflected light rather than heat. What changes is how materials interact with that light.

Water is the headline. It has absorption bands near 970, 1200 and 1450 nm, with another near 1940 nm beyond standard InGaAs. At 1450 nm moisture appears dark, which reveals wet spots, uneven drying and bruises in fruit. A practical technique is a two-wavelength ratio: dividing an image at an absorption band such as 1450 nm by a reference at about 1300 nm cancels much of the variation from lighting and surface shape, leaving a signal related to water at or near the surface. Calibrating that to absolute moisture needs reference samples.

Silicon becomes transparent above about 1100 to 1200 nm, although heavy doping and metal layers reduce transmission, so SWIR can inspect bonded wafers, voids and cracks from behind. Many plastics are translucent enough to show a liquid level through an opaque-looking container, if the wall transmits at the chosen wavelength. Many dyes and inks become transparent, so printing can vanish while carbon-based inks stay dark, which is useful for reading through a printed layer or checking authenticity. Fine haze also scatters less: Rayleigh scattering falls with the fourth power of wavelength, so scattering at 1550 nm is about 60 times weaker than at 550 nm.

Plastics and organic materials also have characteristic absorption bands, which is the basis of SWIR sorting. If two wavelengths separate your materials, an area or line camera with filtered lighting is enough. If they do not, you are in hyperspectral territory, a larger step in data and cost. Carbon-black-pigmented plastics absorb broadly and remain a known limit for SWIR sorting.

  • Moisture mapping, drying uniformity and food sorting.
  • Fill-level checks through opaque-looking plastic containers.
  • Silicon wafer and solar cell inspection, including through-wafer imaging.
  • Ink differentiation, seeing through dyes and checking counterfeit markers.
  • Hot glass and metal process monitoring, and laser beam profiling at 1064 and 1550 nm.

SWIR sensors and lighting

Standard InGaAs sensors respond from about 900 to 1700 nm. Thinned, substrate-removed versions also extend into the visible, which is useful when one camera must cover both, while extended InGaAs reaches about 2200 to 2600 nm at the cost of much higher dark current and stronger cooling. Quantum-dot and germanium-on-silicon detectors are alternatives aimed at lower sensor cost, so compare their quantum efficiency and noise figures directly for your wavelength.

Expect modest pixel counts. Typical formats are 640 × 512 and 1280 × 1024, at pixel pitches of about 5 to 15 µm, and line sensors generally have far fewer pixels than silicon ones. If a silicon job would need 5 MP to cover the field at the required detail, a SWIR version will often need a smaller field, several cameras or a line-scan arrangement. InGaAs also generally shows more fixed-pattern noise and more defective pixels than silicon, so cameras depend on non-uniformity and pixel correction. Those corrections are valid for a given gain, exposure and temperature, so recheck them if conditions change.

Lighting usually has to change too. Normal white and red vision LEDs emit almost nothing useful above about 1000 nm, so existing lighting cannot be reused. Typical SWIR LEDs are centred around 1050, 1200, 1300, 1450, 1550 and 1650 nm, generally with lower optical output than visible LEDs. Tungsten halogen is a strong broadband source across the band, and pairing it with a bandpass filter lets you test several wavelengths, although it adds heat and slower switching. Choose the LED wavelength from the material measurement, because a mismatch of tens of nanometres can matter when absorption bands are narrow.

Safety deserves attention. SWIR light is invisible, so operators get no visual warning and no blink response. Assess lasers under IEC 60825-1 and LED sources under IEC 62471, and do not rely on a wavelength being described as eye-safe without doing the exposure calculation.

UV imaging: fluorescence versus reflected UV

UV imaging covers two different techniques, and confusing them is expensive. UV bands are conventionally UV-A at 315 to 400 nm, UV-B at 280 to 315 nm and UV-C below 280 nm. Most industrial sources sit around 365 to 405 nm, with 405 nm strictly being violet.

In fluorescence imaging the UV light is only the excitation. The material absorbs it and re-emits at a longer, usually visible wavelength, which a standard silicon camera sees through a filter that blocks the excitation. No UV camera or UV lens is needed, and that makes this the first option to try. It suits adhesives and conformal coatings with tracer dyes, security inks, oil films, fluorescent penetrant inspection and optical brighteners in paper. Emission is weak compared with excitation, so filter blocking matters: a monochrome camera with a bandpass filter at the emission peak generally gives the best contrast, and a short-pass filter on the source removes its visible tail.

Reflected UV imaging is different: the camera sees the UV itself. Short wavelengths are absorbed very close to the surface, so the image shows surface-only detail, and fine scatterers show up strongly, with Rayleigh scattering at 365 nm about 5 times stronger than at 550 nm. Scratches, thin films and contaminants on polished parts can stand out, and many plastics and coatings absorb UV, which helps detect transparent films. This needs a UV-capable sensor, usually without standard microlenses and with suitable cover glass, and some sensors respond down to about 200 nm. Ordinary lens assemblies usually lose transmission quickly below about 380 to 400 nm because of the glass types, cements and coatings, so reflected UV generally needs fused silica or similar optics, particularly well below 365 nm.

UV also has material and safety consequences. Exposure limits for eyes and skin apply, so enclose the source, interlock it and assess it under IEC 62471. Long-term UV ageing affects plastics, cable jackets, adhesives and some optical components. UV-C LEDs are far less efficient than 365 nm parts, which limits usable power, and very short wavelengths can generate ozone.

  • Fluorescence: UV source, visible camera, UV-blocking long-pass or emission bandpass filter.
  • Reflected UV: UV source, UV-capable sensor, UV-transmitting lens.
  • Colored-glass long-pass filters can fluoresce under UV; check whether an interference type is needed.
  • Solar-blind imaging below about 280 nm, for example for corona discharge, is a specialist application with very different hardware.

LWIR thermal: measuring emitted radiation

Long-wave infrared, about 8 to 14 µm, is different in kind. Objects near room temperature emit most strongly around 10 µm, so the camera sees emitted radiation and needs no illumination. Image contrast comes from differences in temperature and emissivity. Uncooled microbolometers are the standard detector, typically at 12 to 17 µm pitch with formats up to 640 × 480 being common and larger ones at a premium, NETD figures typically below 50 mK, and frame rates typically of 9, 30 or 60 Hz.

Emissivity is the main trap. Matte paint, most plastics, paper and ceramics are typically around 0.9 or above, oxidised steel about 0.7 to 0.9, and even heavily oxidised aluminium only about 0.2 to 0.3, while polished aluminium or stainless steel may be around 0.05 to 0.2. A polished part mostly reflects the temperature of whatever it faces, so a reading can be badly wrong and can even show the operator's reflection. Use a known-emissivity tape or paint, measure at a heavily oxidised area on steel, or use relative comparison rather than absolute temperature. Typical radiometric accuracy is about ±2 °C or ±2% of reading, so the sensitivity implied by NETD should not be confused with absolute accuracy.

Bolometers cannot freeze motion the way a global shutter does. They respond with a thermal time constant, typically about 10 ms, so a part moving at 500 mm/s through a field with 1 mm pixels smears across roughly 5 pixels. For moving product, slow the line, widen the pixels or accept lower spatial resolution. Cooled photon-detecting cameras, typically MWIR at 3 to 5 µm, offer far shorter integration times and higher frame rates, at much higher system cost.

Spatial resolution also limits measurement. A target needs to cover several pixels, at least 3 × 3 and preferably more, for a trustworthy temperature, otherwise the reading averages in the background. With 1 mm pixels, trust temperature on features larger than about 3 to 5 mm. Bolometer cameras also run a periodic flat-field correction, usually with a mechanical shutter that blinds the camera briefly, so make sure it cannot fall during a critical capture.

  • Typical uses: heat-seal integrity, adhesive and sealant presence, electronics power-up anomalies, cook and process temperature, electrical cabinet hot spots.
  • Active thermography, using a flash or induction pulse and observing the decay, can reveal subsurface voids and delaminations.
  • Ordinary glass is opaque in LWIR, so a thermal camera sees the glass surface and its reflections, not what is behind it.
  • Thin polyethylene film is partly transparent in LWIR, so check whether a wrap affects the reading.

Optics and filters change with wavelength

The diffraction spot grows in proportion to wavelength. The Airy disc diameter is about 2.44 × λ × N: 3.6 µm at 365 nm and f/4, 5.4 µm at 550 nm and f/4, 15 µm at 1550 nm and f/4, and 24 µm at 10 µm and f/1. That is why LWIR lenses are so fast and pixels so large. It also has a practical result in SWIR: a 5 µm InGaAs pixel at f/4 receives a spot about 3 pixels wide, so you need a faster aperture such as f/2 (about 7.6 µm) to use the sensor, and you pay for it in depth of field.

Lens design matters as well. A visible lens may transmit SWIR through its glass, but coatings optimised for 400 to 700 nm reflect more in SWIR, which lowers contrast and raises flare, and the focus position shifts. Fine for a first test, but use SWIR-corrected optics for production, and focus at the working wavelength. Broadband illumination with an uncorrected lens adds chromatic blur. LWIR lenses use germanium, chalcogenide or zinc selenide, because glass does not transmit there, and protective windows must follow the same logic.

Filters need rechecking for each band. Many visible and NIR filters specify out-of-band blocking only up to the limit of silicon, about 1100 to 1200 nm, so they can leak on an InGaAs camera. Specify blocking across the sensor's entire response. Interference filters also shift to shorter wavelengths as angle of incidence increases, which matters with wide-angle lenses and narrow bands. For fluorescence, specify strong blocking of the excitation line, because it is usually far brighter than the emission you want to see.

  • Protective windows: optical glass for visible and SWIR, fused silica for shorter UV, germanium or similar for LWIR.
  • Lens check: rated wavelength range, coating, resolving power at the sensor's pitch.
  • Nyquist frequency is 500 / pixel pitch in µm, in lp/mm: 100 lp/mm at 5 µm and about 33 lp/mm at 15 µm.
  • Filter check: pass band, blocking range to the end of sensor response, angle sensitivity, thread and thickness.

Cost, cooling and compliance trade-offs

As a rough ranking, silicon cameras are the lowest cost, uncooled LWIR sits higher, InGaAs SWIR is typically many times the cost of a silicon camera of similar format, and cooled MWIR is highest. Reflected UV can also add substantial cost through its lenses and sensor. Always look at the complete chain, because specialised lenses and lighting can be a large part of the total, and lower pixel counts can force more cameras for the same coverage.

Cooling depends on the task, not only the band. Standard InGaAs cameras at short exposures may run uncooled or with single-stage thermoelectric stabilisation, because dark current matters little over a few milliseconds. Long exposures, and particularly extended-wavelength sensors, generally need stronger thermoelectric cooling, which adds power, heat to remove and sealing against condensation. Uncooled LWIR cameras need no active cooling, but allow warm-up time and keep their ambient stable for good radiometric results. Cooled MWIR uses mechanical cryocoolers, which have a finite service life that belongs in the maintenance plan.

Some thermal and SWIR cameras fall under dual-use export-control regulations. Low-frame-rate thermal variants of around 9 Hz exist largely for that reason. Check the classification before planning cross-border shipment or a machine for export, because it affects paperwork and project timing.

A sensible path is to measure first, then specify. Characterise the samples, confirm the wavelength with a test image, and only then commit to a sensor, lens and lighting combination. Include the worst real parts, because the bands in this guide are often chosen to catch subtle differences that disappear with natural product variation.

Whether a defect shows up outside the visible band depends on the material, so it is worth proving on samples before buying optics and lighting. AIS Vision runs that kind of application validation and, where the contrast is real but varies from part to part, deep-learning inspection with Rosepetal can take over from fixed thresholds.

  • First test NIR with a silicon camera before moving to SWIR.
  • First test UV fluorescence with a visible camera before moving to reflected UV.
  • Treat thermal as relative unless emissivity is known and controlled.
  • Include lens, lighting, filter, cooling and export paperwork in the project plan, not just the camera.

Frequently asked questions

Related categories

  • SWIR / UV cameras
  • Thermal (LWIR) cameras
  • Optical filters

Related guides

Recommended hardware

SWIR / UV cameras

All swir / uv cameras →
  • iRAYPLE AHS130MG000E machine vision camera
    iRAYPLEiRAYPLE AHS130MG000EAHS130MG000E
    • Area Scan
    • GigE, PoE
    • 1.3 MP
    • Global
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron STC-SBS34CXP121-SWIRU machine vision camera
    Omron / SentechOmron STC-SBS34CXP121-SWIRUSTC-SBS34CXP121-SWIRU
    • Area Scan Camera
    • CoaXPress Standard Version 2.0
    • 0.3MP
    • Global Shutter
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-CI013-GS-TF machine vision camera
    HikrobotHikrobot MV-CI013-GS-TFMV-CI013-GS-TF
    • Area scan
    • GigE
    • 1.3 MP
    • 91 fps @ 1280 × 1024
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Thermal (LWIR) cameras

All thermal (lwir) cameras →
  • Hikrobot MV-CI003-GL-N15 machine vision camera
    HikrobotHikrobot MV-CI003-GL-N15MV-CI003-GL-N15
    • Area scan
    • GigE
    • 0.3 MP
    • 50 fps @ 640 × 512
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-CI003-GL-N25 machine vision camera
    HikrobotHikrobot MV-CI003-GL-N25MV-CI003-GL-N25
    • Area scan
    • GigE
    • 0.3 MP
    • 50 fps @ 640 × 512
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-CI003-GL-N6 machine vision camera
    HikrobotHikrobot MV-CI003-GL-N6MV-CI003-GL-N6
    • Area scan
    • GigE
    • 0.3 MP
    • 50 fps @ 640 × 512
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Hikrobot MV-CI003-GL-N35 machine vision camera
    HikrobotHikrobot MV-CI003-GL-N35MV-CI003-GL-N35
    • Area scan
    • GigE
    • 0.3 MP
    • 50 fps @ 640 × 512
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • DCM Sistemes VPF Series Polarizer Filter machine vision optical filter
    DCM SistemesVPF Series Polarizer FilterVPF Series
    • protector
    • Match companion lighting unit footprint (from approx. 40×34 mm to 307×292 mm depending on model)
    • 0–40°C
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Omron 3Z4S-LE SV-PLA225 machine vision lens
    Omron / SentechOmron 3Z4S-LE SV-PLA2253Z4S-LE SV-PLA225
    • Polarizing Filter
    • M22.5 P0.5
    • 7.2 g
    • For lenses for C-mount cameras
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View
  • Datalogic FLT-ORA-BP-590 machine vision optical filter
    Datalogic / DatasensingDatalogic FLT-ORA-BP-590FLT-ORA-BP-590
    • bandpass
    • 560-600nm
    • M25.5
    • Rosepetal compatible
    • Recommended by AIS Vision
    On request
    View

Request a technical quote

If you have a specific application, we help you select the right hardware and validate it.