Basler IP-Housing Lens Tube 80mm — IP67 lens housing (lens tube), size 80 mm x 55 mm x 55 mm, weight 69 g, material Glass filled nylon, high impact, lens Ø up to 47 mm, operating 0 °C - 50 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M50 adapter ring is required (article number: 2200002586). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), no adapter ring is required. However, for complete protection of the camera, a suitable cable gland is also required. Only the combination of camera housing, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
80 mm x 55 mm x 55 mm
Weight
69 g
Housing material
Glass filled nylon, high impact
Operating temperature
0 °C - 50 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-5028-5M f50mm, Basler Lens C23-3520-5M f35mm, Basler Lens C23-7538-16M f75mm, Basler Lens C125-2522-5M f25mm, Basler Lens C11-3520-12M f35mm, Basler Lens C23-5028-16M f50mm, Basler Lens C23-3528-16M f35mm, Basler Lens C23-5026-2M f50mm +2 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M50 Adapter Ring
Long lenses need long tubes, and the 80 mm tube is built for them: its 10 compatible lenses include f25, f35, f50 and f75 types. A long focal length narrows the field. As an example, with a thin-lens estimate, an f75 lens on a sensor 8.8 mm wide at 500 mm from the lens sees about 8.8 mm × (500 − 75) mm ÷ 75 mm ≈ 50 mm across, so these lenses suit small fields viewed from a distance.
The tube weighs 69 g. Its window is BK7 glass with an anti-reflective coating, the seal is EPDM and the body is glass-filled nylon; it is rated 0 °C to 50 °C and takes lenses up to 47 mm in diameter.
Best for
Long-focal-length lenses (f35, f50, f75 types) that watch a small field from a safe distance behind a window.
Small fields on a large machine, such as one connector or label on an assembly, viewed from outside the work area.
ace and ace 2 set-ups on cameras with USB, CXP, GMSL or GigE housings, all of which are compatible with this tube.
Selection notes
Long lenses magnify vibration as well as detail: a stiff mount matters more here than with short lenses.
Only 10 lenses are compatible with this tube; verify your exact model before ordering.
An ace 2 IP67 camera needs the M28 to M50 adapter ring (article number 2200002586); the separate camera housings need none.
For shorter lenses use the 50, 60 or 70 mm tubes, which give a shorter overall stack.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-5028-5M f50mm, Basler Lens C23-3520-5M f35mm, Basler Lens C23-7538-16M f75mm, Basler Lens C125-2522-5M f25mm, Basler Lens C11-3520-12M f35mm, Basler Lens C23-5028-16M f50mm, Basler Lens C23-3528-16M f35mm, Basler Lens C23-5026-2M f50mm +2 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M50 Adapter Ring
Specifications: Environment
Operating temperature
0 °C - 50 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Ten Basler lenses are compatible, including f25, f35, f50 and f75 types.
No. Basler gives IP67 only for camera housing, lens housing and cable gland together.