Basler IP-Housing Medium Lens Tube 100mm — IP67 lens housing (lens tube), size 100 mm x 80 mm x 80 mm, material Type 2 anodised aluminium, lens Ø up to 72 mm, operating -20 °C - 80 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M75 adapter ring is required (article number: 2200002660). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), the M50 to M75 adapter ring is required (article number: 2200002628). For complete protection of the camera, a suitable cable gland is also required. Only the combination of camera, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
100 mm x 80 mm x 80 mm
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-5028-5M f50mm, Basler Lens C11-2520-12M f25mm, Basler Lens C11-5020-12M f50mm, Basler Lens C23-3520-5M f35mm, Basler Lens C23-7538-16M f75mm, Basler Lens C12-5024-25M +18 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
The Medium tube is for lenses that do not fit the standard tubes: its lens limit is 72 mm in diameter, against 47 mm for the nylon IP-Housing Lens Tubes, and 26 Basler lenses are compatible. It is made of Type 2 anodised aluminium and is specified for −20 °C to 80 °C, against 0 °C to 50 °C for the nylon tubes.
The body is 100 mm × 80 mm × 80 mm, so against the 55 mm × 55 mm cross-section of a camera housing it overhangs by (80 − 55) / 2 = 12.5 mm on each side. Check clearance for brackets, lights and neighbouring parts. On a 95.9 mm camera housing the stack is 95.9 + 100 = 195.9 mm before the adapter ring. The ring is not optional: an M50 to M75 ring (article number 2200002628) on the camera housings, or an M28 to M75 ring (2200002660) directly on an ace 2 IP67 camera. The window is BK7 with an anti-reflective coating and the seal is EPDM.
Best for
Large-diameter lenses of up to 72 mm that the 47 mm nylon tubes cannot hold.
Lens ends that see temperatures beyond the 0 to 50 °C of the nylon tubes: this tube is specified for −20 °C to 80 °C, though the camera and housing limits still apply.
Long lenses that need the full 100 mm of tube length, among the 26 compatible models.
Selection notes
Order the adapter ring with the tube: M50 to M75 for the camera housings, M28 to M75 for the ace 2 IP67 camera.
The camera housings accept lenses up to 47 mm in diameter, so confirm the lens appears among the compatible models rather than assuming 72 mm applies to the whole stack.
The camera housings are also compatible with Medium tubes of 60, 70 and 80 mm; choose the shortest that holds the lens.
Basler gives IP67 only for the combination of camera housing, this lens tube and a cable gland.
The tube itself is specified for −20 °C to 80 °C, but the camera housings it mounts on are specified for 0 °C to 50 °C, so the assembled stack is limited by the narrower range.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-5028-5M f50mm, Basler Lens C11-2520-12M f25mm, Basler Lens C11-5020-12M f50mm, Basler Lens C23-3520-5M f35mm, Basler Lens C23-7538-16M f75mm, Basler Lens C12-5024-25M +18 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Yes. Use the M50 to M75 ring (article number 2200002628) on the camera housings, or the M28 to M75 ring (article number 2200002660) directly on an ace 2 IP67 camera.
72 mm, against 47 mm for the nylon IP-Housing Lens Tubes.