Basler IP-Housing Medium Lens Tube 60mm — IP67 lens housing (lens tube), size 60 mm x 80 mm x 80 mm, material Type 2 anodised aluminium, lens Ø up to 77 mm, operating -20 °C - 80 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M75 adapter ring is required (article number: 2200002660). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), the M50 to M75 adapter ring is required (article number: 2200002628). For complete protection of the camera, a suitable cable gland is also required. Only the combination of camera, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
60 mm x 80 mm x 80 mm
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-0824-5M f8mm, Basler Lens C23-1224-5M f12mm, Basler Lens C125-0618-5M f6mm, Basler Lens C23-0816-2M f8mm, Basler Lens C125-1218-5M f12mm, Basler Lens C125-0818-5M f8mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1216-2M f12mm +19 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE; Lens Accessories: Basler M50 to M75 Adapter Ring, Basler M28 to M75 Adapter Ring
At 60 mm, this is the shortest of the Medium lens tubes, which run 60, 70, 80, 90 and 100 mm. The body is 80 mm × 80 mm in cross-section and takes lenses up to 77 mm in outer diameter, which is the reason to choose the Medium family over the 55 mm-wide IP-Housing Lens Tube 60mm, which takes lenses only up to 47 mm. It is Type 2 anodised aluminium with an EPDM seal and a BK7 window with an anti-reflective coating, rated -20 °C to 80 °C.
Compatibility is by lens model. Basler gives 27 compatible lenses for this tube, among them the f6 C125-0618-5M, the f8 C23-0824-5M and the f25 C23-2518-5M, while the 70 mm tube has 36, so the lists differ and a lens that suits one length is not automatically right for another. The tube needs an adapter ring: M28 to M75 on an ace 2 IP67 camera, M50 to M75 on a separately available IP67 camera housing. Basler gives IP67 only for camera housing, lens housing and cable gland together.
Best for
Sealing a short lens such as the f6 C125-0618-5M or the f8 C23-0824-5M, both compatible with this tube, when you want the least length among the Medium tubes.
Lenses between 47 mm and 77 mm in outer diameter, which the 55 mm-wide IP-Housing Lens Tube 60mm cannot take.
Machines where space along the optical axis is limited: this tube is 10 mm shorter than the 70 mm Medium tube.
Selection notes
Measure the lens from the mount face to the front of its glass, hood or filter and compare it with the 60 mm body; the usable length inside is shorter than the outside length because of the walls and window. If it does not clear, step up to the 70 mm tube.
The tube is rated -20 °C to 80 °C, but on a camera housing the housing and the M25 cable gland are rated 0 °C to 50 °C, so in a cold store or near a hot process the set is limited by those parts, not by the tube.
Choose the ring for your camera before ordering: article number 2200002660 (M28 to M75) for an ace 2 IP67 camera, 2200002628 (M50 to M75) for a camera housing.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-0824-5M f8mm, Basler Lens C23-1224-5M f12mm, Basler Lens C125-0618-5M f6mm, Basler Lens C23-0816-2M f8mm, Basler Lens C125-1218-5M f12mm, Basler Lens C125-0818-5M f8mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1216-2M f12mm +19 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE; Lens Accessories: Basler M50 to M75 Adapter Ring, Basler M28 to M75 Adapter Ring
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Basler gives 27 compatible lenses, including the f6 C125-0618-5M, the f12 C23-1224-5M and the f25 C23-2518-5M. The tube takes lenses up to 77 mm in outer diameter, but confirm your exact model.
No. IP67 applies to camera housing, lens housing and cable gland used together.