Basler IP-Housing Medium Lens Tube 70mm — IP67 lens housing (lens tube), size 70 mm x 80 mm x 80 mm, material Type 2 anodised aluminium, lens Ø up to 77 mm, operating -20 °C - 80 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M75 adapter ring is required (article number: 2200002660). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), the M50 to M75 adapter ring is required (article number: 2200002628). For complete protection of the camera, a suitable cable gland is also required. Only the combination of camera, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
70 mm x 80 mm x 80 mm
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-1224-5M f12mm, Basler Lens C11-1620-12M f16mm, Basler Lens C11-0824-12M f8.5mm, Basler Lens C23-0816-2M f8mm, Basler Lens C11-1220-12M f12mm, Basler Lens C125-1218-5M f12mm, Basler Lens C125-0818-5M f8mm, Basler Lens C23-2518-5M f25mm +28 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
This is the Medium tube with the most compatible lenses: 36, against 27 for the 60 mm tube and 32 each for the 80 mm and 90 mm tubes. When a lens has to be housed and the length is still open, check this tube first. Several of the 36 share a focal length but are different designs: two f8 types (C23-0816-2M and C125-0818-5M) and three f12 types (C23-1224-5M, C11-1220-12M and C125-1218-5M), so match the exact model, not the focal length.
The 70 mm × 80 mm × 80 mm body is Type 2 anodised aluminium with a BK7 window, anti-reflective coated, rated -20 °C to 80 °C, and it takes lenses up to 77 mm in outer diameter. Its EPDM seal copes with water and weather but typically swells in mineral oil and many solvents, so on lines with cutting fluid or oil mist check the seal against your fluid before relying on IP67. Mounting needs a ring: M28 to M75 on an ace 2 IP67 camera, M50 to M75 on a separately available IP67 camera housing.
Best for
First installs where the lens is not yet final, since 36 compatible lenses leave room to change the focal length without changing the housing.
Standardising several stations on one housing: stations whose lenses are among the 36 can share one tube length and one spare.
Housing a mid-range lens such as the f8.5 C11-0824-12M, the f16 C11-1620-12M or the f25 C23-2518-5M, all compatible with this tube.
Selection notes
Check the exact lens model against the tube. If a lens is too long, the 80 mm tube adds 10 mm; if it has room to spare, the 60 mm tube saves 10 mm of stack length.
If the lens is no wider than 47 mm, also check the compact IP-Housing Lens Tube 70mm (55 mm × 55 mm): it mounts on a camera housing without an adapter ring and keeps the unit smaller.
Focus and aperture are out of reach once the tube is closed, so set both on the bench with a test target at the working distance.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-1224-5M f12mm, Basler Lens C11-1620-12M f16mm, Basler Lens C11-0824-12M f8.5mm, Basler Lens C23-0816-2M f8mm, Basler Lens C11-1220-12M f12mm, Basler Lens C125-1218-5M f12mm, Basler Lens C125-0818-5M f8mm, Basler Lens C23-2518-5M f25mm +28 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
36 lenses are compatible, among them the f16 C11-1620-12M, the f12 C11-1220-12M and the f25 C23-2518-5M. Several designs share a focal length, so check the exact model.
Yes, through the M28 to M75 adapter ring (article number 2200002660). On the separately available IP67 camera housings the M50 to M75 ring (article number 2200002628) is used instead.