Basler IP-Housing Medium Lens Tube 80mm — IP67 lens housing (lens tube), size 80 mm x 80 mm x 80 mm, material Type 2 anodised aluminium, lens Ø up to 77 mm, operating -20 °C - 80 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M75 adapter ring is required (article number: 2200002660). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), the M50 to M75 adapter ring is required (article number: 2200002628). For complete protection of the camera, a suitable cable gland is also required. Only the combination of camera, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
80 mm x 80 mm x 80 mm
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-1224-5M f12mm, Basler Lens C11-1620-12M f16mm, Basler Lens C23-0816-2M f8mm, Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1216-2M f12mm, Basler Lens C23-1620-5M f16mm, Basler Lens C11-2520-12M f25mm +24 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
The 80 mm tube is as long as it is wide and tall (80 mm × 80 mm × 80 mm). Basler gives 32 compatible lenses for it, among them the f16 C23-1620-5M and the f25 C11-2520-12M. The f25 C23-2518-5M and the f12 C125-1218-5M are also compatible with the 60, 70 and 90 mm tubes, so for lenses like these the length is a free choice and the longer body only adds 20 mm of room over the 60 mm tube.
The window is BK7 glass with an anti-reflective coating, which reduces reflection but does not remove it: a ring or bar light beside the tube can still shine across the glass as veiling glare. Aim the lights so they do not graze the window, or shield it, and test with the real lighting before fixing the geometry. The body is Type 2 anodised aluminium with an EPDM seal, rated -20 °C to 80 °C, and takes lenses up to 77 mm in outer diameter.
Best for
Housing an f16 or f25 lens such as the C23-1620-5M or the C11-2520-12M, both compatible with this tube, in a dusty or splash-exposed cell.
Replacing a 70 mm tube when a lens or hood turns out longer than expected: the 80 mm tube adds 10 mm and uses the same adapter rings.
Lenses compatible with several Medium lengths, such as the f25 C23-2518-5M, where a hood or filter at the front decides how much length is needed.
Selection notes
Check both dimensions of the lens: outer diameter up to 77 mm, and total length including hood, filter and focusing extension against the 80 mm body.
Choose the shortest tube that clears the lens: for a lens compatible with several lengths, a longer tube only adds stack length once lens, hood and filter already clear.
Allow for the 80 mm × 80 mm cross-section when planning brackets and cable routing; it is wider than the 55 mm compact tubes.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C23-1224-5M f12mm, Basler Lens C11-1620-12M f16mm, Basler Lens C23-0816-2M f8mm, Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1216-2M f12mm, Basler Lens C23-1620-5M f16mm, Basler Lens C11-2520-12M f25mm +24 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
No. An adapter ring goes between them: the M50 to M75 ring (article number 2200002628) on the separately available IP67 camera housings, or the M28 to M75 ring (article number 2200002660) on an ace 2 IP67 camera.
IP67 means dust-tight and protected against temporary immersion, typically 1 m for 30 minutes. It is not a rating for high-pressure washdown, and Basler gives it only for camera housing, lens housing and cable gland together.