Basler IP-Housing Medium Lens Tube 90mm — IP67 lens housing (lens tube), size 90 mm x 80 mm x 80 mm, material Type 2 anodised aluminium, lens Ø up to 77 mm, operating -20 °C - 80 °C, IP67. Note: To mount the lens housing directly on an ace 2 IP67 camera, the M28 to M75 adapter ring is required (article number: 2200002660). Note: To mount the lens housing on one of the separately available IP67 camera housings (models: ace Classic, ace U, ace 2 – except ace 2 IP67 – and racer 2 S), the M50 to M75 adapter ring is required (article number: 2200002628). For complete protection of the camera, a suitable cable gland is also required. Only the combination of camera, lens housing, and cable gland ensures reliable IP67 protection.
Brand
Basler
Dimensions
90 mm x 80 mm x 80 mm
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C11-1620-12M f16mm, Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1216-2M f12mm, Basler Lens C23-1620-5M f16mm, Basler Lens C11-2520-12M f25mm, Basler Lens C23-5028-5M f50mm, Basler Lens C11-5020-12M f50mm +24 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
Long focal lengths are the reason to look at the 90 mm tube: its compatible lenses include two f50 types, the C23-5028-5M and the C11-5020-12M, alongside f12, f16 and f25 lenses, 32 in all. The body is 90 mm × 80 mm × 80 mm, Type 2 anodised aluminium with an EPDM seal and an anti-reflective BK7 window, rated -20 °C to 80 °C.
The IP-Housing Medium Lens Tube 100mm is 10 mm longer and its compatible lenses include an f75 (C23-7538-16M), but it takes lenses only up to 72 mm in outer diameter, against 77 mm here. A lens between 72 mm and 77 mm wide that needs more than 80 mm of tube therefore belongs in this one.
Best for
Housing an f50 lens such as the C23-5028-5M or the C11-5020-12M, both compatible with this tube, for small fields viewed from a distance in a sealed station.
Lenses between 72 mm and 77 mm in outer diameter that need more than 80 mm of tube: this tube takes up to 77 mm, the 100 mm tube only 72 mm.
Replacing an 80 mm tube when a long lens, hood or filter does not clear: the 90 mm tube adds 10 mm and uses the same rings.
Selection notes
Confirm your exact lens model is compatible and measure its length with hood or filter. Some lenses grow longer when focused close, so measure at the closest working distance you will use.
The tube needs the M28 to M75 ring on an ace 2 IP67 camera or the M50 to M75 ring on a camera housing, and Basler gives IP67 only with the cable gland added.
Compare with the 80 mm tube first: the f16 C11-1620-12M and the f25 C11-2520-12M are compatible with both, so choose 90 mm only if the lens, hood or filter needs the extra 10 mm.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2, Basler ace; Lenses: Basler Lens C11-1620-12M f16mm, Basler Lens C125-1218-5M f12mm, Basler Lens C23-2518-5M f25mm, Basler Lens C23-1216-2M f12mm, Basler Lens C23-1620-5M f16mm, Basler Lens C11-2520-12M f25mm, Basler Lens C23-5028-5M f50mm, Basler Lens C11-5020-12M f50mm +24 more; Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler M28 to M75 Adapter Ring, Basler M50 to M75 Adapter Ring
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Two f50 types, the C23-5028-5M and the C11-5020-12M, among 32 compatible lenses in all.
No. The Medium tubes from 60 to 100 mm all use the M28 to M75 ring on an ace 2 IP67 camera or the M50 to M75 ring on a camera housing.