Basler M28 to M75 Adapter Ring — IP67 lens-housing adapter ring, material Type 2 anodised aluminium, operating -20 °C - 80 °C, IP67. This protects your vision system from dust and water in accordance with the IP67 standard, ensuring reliable performance in demanding environmental conditions.
Brand
Basler
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Area Scan Cameras: Basler ace 2; Lens Accessories: Basler IP-Housing Medium Lens Tube 80mm, Basler IP-Housing Medium Lens Tube 70mm, Basler IP-Housing Medium Lens Tube 90mm, Basler IP-Housing Medium Lens Tube 100mm, Basler IP-Housing Medium Lens Tube 60mm
This ring carries the Medium lens tubes of 60, 70, 80, 90 and 100 mm onto an ace 2 IP67 camera. Choose it when the lens is too wide for the compact tubes: the Medium tubes are 80 mm × 80 mm and take lenses up to 77 mm in outer diameter (72 mm for the 100 mm tube), against 47 mm for the 55 mm-wide compact tubes that use the M28 to M50 ring.
The camera route decides the ring. An ace 2 IP67 camera takes this one; a camera in one of the separately available IP67 housings takes the M50 to M75 ring. Both end in the same Medium tubes. The ring is not the constraint: all five lengths sit on it, so you choose the tube by the lens. It is Type 2 anodised aluminium rated -20 °C to 80 °C with an EPDM seal, and Basler gives IP67 for the combination of camera housing, lens housing and cable gland.
Best for
Putting a Medium tube on an ace 2 IP67 camera so that a lens up to 77 mm in outer diameter is sealed without a separate camera housing.
Projects where the lens may change: this one ring carries all five Medium lengths, so only the tube is replaced.
Long lenses, or a hood or filter at the lens front, that need the 90 mm or 100 mm tube, both of which sit on this ring.
Selection notes
Confirm the camera first: this ring is for the ace 2 IP67; a camera in a separate IP67 housing needs the M50 to M75 ring.
Pick the tube from the lens (diameter, length, compatibility); the ring then fits whichever Medium length you choose.
Keep the threads clean and the EPDM seal seated when assembling, and replace a damaged seal instead of reusing it.
Specifications: General
Brand
Basler
Compatible with
Area Scan Cameras: Basler ace 2; Lens Accessories: Basler IP-Housing Medium Lens Tube 80mm, Basler IP-Housing Medium Lens Tube 70mm, Basler IP-Housing Medium Lens Tube 90mm, Basler IP-Housing Medium Lens Tube 100mm, Basler IP-Housing Medium Lens Tube 60mm
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
All five Medium tubes: 60, 70, 80, 90 and 100 mm.
For the ace 2 IP67 camera. The camera housings use the M50 to M75 ring.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE