Basler M50 to M75 Adapter Ring — IP67 lens-housing adapter ring, material Type 2 anodised aluminium, operating -20 °C - 80 °C, IP67. This protects your vision system from dust and water in accordance with the IP67 standard, ensuring reliable performance in demanding environmental conditions.
Brand
Basler
Housing material
Type 2 anodised aluminium
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Compatible with
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler IP-Housing Medium Lens Tube 70mm, Basler IP-Housing Medium Lens Tube 90mm, Basler IP-Housing Medium Lens Tube 100mm, Basler IP-Housing Medium Lens Tube 60mm, Basler IP-Housing Medium Lens Tube 80mm
This ring is how a larger lens gets onto a camera housing. The IP67 camera housings take lenses up to 47 mm in outer diameter; the ring joins their M50 side and carries a Medium tube on its M75 side, which takes lenses up to 77 mm (72 mm for the 100 mm tube).
It fits the housings for ace 2 GigE, ace 2 USB / CXP / GMSL, ace USB and ace GigE, and the Medium tubes of 60, 70, 80, 90 and 100 mm. The compact IP-Housing Lens Tubes of 50 to 80 mm mount on these housings without a ring, so the ring is only needed for the Medium family. An ace 2 IP67 camera has no separate housing and takes the M28 to M75 ring instead. The ring is Type 2 anodised aluminium rated -20 °C to 80 °C with an EPDM seal; the housings are rated 0 °C to 50 °C.
Best for
Housed cameras that need a lens wider than 47 mm: this ring adds a Medium tube, which takes lenses up to 77 mm, to the housing.
Plants with mixed ace and ace 2 stations in IP67 housings: one ring type serves all four housings, which keeps spares simple.
Lenses that need the full 100 mm tube length on a camera housing, since the ring accepts every Medium length from 60 to 100 mm.
Selection notes
Confirm the camera sits in one of the four housings; with an ace 2 IP67 camera use the M28 to M75 ring.
Do not order it for the compact IP-Housing Lens Tubes; those need no ring on a camera housing.
Choose the Medium tube length by the lens, then add this ring; a cable gland still completes the set, and Basler gives IP67 only for all parts together.
Specifications: General
Brand
Basler
Compatible with
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace GigE, Basler Camera housing ace USB; Lens Accessories: Basler IP-Housing Medium Lens Tube 70mm, Basler IP-Housing Medium Lens Tube 90mm, Basler IP-Housing Medium Lens Tube 100mm, Basler IP-Housing Medium Lens Tube 60mm, Basler IP-Housing Medium Lens Tube 80mm
Specifications: Environment
Operating temperature
-20 °C - 80 °C
IP rating
IP67 (Basler protection class; Basler: camera housing + lens housing + cable gland together give IP67)
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
The housings for ace 2 GigE, ace 2 USB / CXP / GMSL, ace USB and ace GigE.
Any Medium lens tube from 60 mm to 100 mm in length.
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE
Camera Housing: Basler Camera housing ace 2 GigE, Basler Camera housing ace 2 USB / CXP / GMSL, Basler Camera housing ace USB, Basler Camera housing ace GigE