Basler Power-I/O Cable, M8 6p/open, P, IP67 (5–10 m)
Power-I/O Cable, M8 6p/open, P, IP67
Basler Power-I/O Cable, M8 6p/open, P, IP67 — I/O / power cable, M8 6-pin (camera side), to none (open end) (host side), static installation, IP67 (Basler model name; for ace 2 IP67 cameras), 2 lengths 5–10 m. The cable is used to control the I/O ports of the ace 2 IP67 cameras and can also be used for power supply.
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Made for the ace 2 IP67 cameras, this lead carries an IP67 designation so the cable does not become the weak point of an otherwise sealed installation. It controls the camera's I/O ports and can also supply power. IP67 typically means dust-tight and tolerant of temporary immersion; it applies to a correctly seated, fully tightened M8 connection, not to the open end that you cut and wire yourself, which belongs inside an enclosure.
Lengths are 5 m and 10 m, with an M8 6-pin connector on the camera side. The cable is for static installation, so IP67 here describes sealing, not flex life. IP67 also does not mean washdown: high-pressure jets are covered by different ratings, typically IP66 or IP69K, so check the plant's cleaning regime.
Best for
Dusty or damp lines using ace 2 IP67 cameras, where the cable entry is the seal most at risk.
Stations that bring trigger I/O and supply to the camera through one M8 lead, which reduces the number of cables to route to the camera.
Fixed installations with the cabinet 5 m or 10 m away and a route that never moves, with the open end terminated inside the cabinet.
Selection notes
Pair it with the ace 2 IP67 camera it is named for. For other cameras, such as boost, Basler UV cameras and racer 2, see the Power-I/O Cable, M8 6p/open, P.
Terminate the open end in a protected space, because the rating ends at the mated connector.
Do not use it in drag chains or on moving cameras.
Specifications: General
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Compatible with
Area Scan Cameras: Basler ace 2
Specifications: Interface
Connector A
M8 6-pin (camera side)
Connector B
none (open end) (host side)
Connection
M8 (M8 6-pin)
Specifications: Environment
IP rating
IP67 (Basler model name; for ace 2 IP67 cameras)
Specifications: Mechanical
Cable length
5–10 m (5, 10 m)
High-flex / drag chain
No — static installation (Basler: "static")
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
It ties the cable to the ace 2 IP67 cameras it is made for; the rating applies while the M8 connector is correctly seated and tightened.
Yes. Basler states that it controls the I/O ports of the ace 2 IP67 cameras and can also be used for power supply.