Basler Power-I/O Cable RS-422 M8 6p/open — I/O / power cable, M8 6-pin (camera side), to none (open end) (host side), static installation, length 10 m. This cable helps reduce electromagnetic interference, especially over longer distances, and features an integrated signal converter. It converts RS-422 differential signals into single-ended signals that are compatible with the GPIO and optocoupled I/O ports of the Basler ace 2 and racer 2 S cameras.
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Cable length
10 m
Connector A
M8 6-pin (camera side)
Connector B
none (open end) (host side)
High-flex / drag chain
No — static installation (Basler: "static")
Connection
M8 (M8 6-pin)
Compatible with
Area Scan Cameras: Basler ace 2; Line Scan Cameras: Basler racer 2
This cable is about signal conversion, not only length. An integrated converter turns RS-422 differential signals into the single-ended signals that the GPIO and optocoupled I/O ports of the ace 2 and racer 2 S cameras expect. Basler says the cable helps reduce electromagnetic interference, especially over longer distances such as this 10 m run.
RS-422 is the output standard of many encoders and motion controllers, so a typical use is triggering a line-scan camera from an encoder. As an example, a web moving at 2 m/s imaged at a 0.05 mm line pitch needs 2000 mm/s ÷ 0.05 mm = 40 000 line triggers per second, so the encoder pulse train, before any scaling in the camera, has to arrive intact at that rate. Ask us for the converter's maximum pulse frequency and check it against your real line rate. The host end is open and the cable is for static installation.
Best for
racer 2 S line-scan stations triggered by an RS-422 encoder on a long run, such as a web or conveyor drive next to motors.
ace 2 cameras that receive trigger signals from a motion controller or encoder interface with RS-422 outputs.
Cabinets and machine frames where drives, contactors and frequency inverters share the cable route with the trigger signals.
Selection notes
Confirm that your encoder or controller outputs RS-422 differential pairs. For a single-ended source use the Power-I/O Cable, M8 6p/open, P (5 m or 10 m).
Land each differential pair on its matching conductors: swapping the two wires of one pair inverts that signal, which for a quadrature encoder reverses the counted direction.
Which GPIO or optocoupled port carries which signal depends on the camera, so check the pin assignment in its manual.
Specifications: General
Brand
Basler
Cable type
I/O / power — Basler type "I/O / Power Cable", interface "I/O"
Compatible with
Area Scan Cameras: Basler ace 2; Line Scan Cameras: Basler racer 2
Specifications: Interface
Connector A
M8 6-pin (camera side)
Connector B
none (open end) (host side)
Connection
M8 (M8 6-pin)
Specifications: Mechanical
Cable length
10 m
High-flex / drag chain
No — static installation (Basler: "static")
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
The camera's I/O ports are single-ended. This cable's integrated converter handles the differential-to-single-ended step, so the encoder's signals reach the camera in a form it accepts.
The ace 2 area-scan and racer 2 line-scan cameras; the converter output is designed for the GPIO and optocoupled I/O ports of the ace 2 and racer 2 S.