Basler SLP Cable, HRS 6p/TBL-S, P — lighting cable, Hirose 6-pin (HR10A-7P-6S) (camera side), to SLP-Connector (host side), length 3 m. Cable for connection between Basler ace U or L and Basler Camera Light Series.
Brand
Basler
Cable type
Lighting cable — Basler type "Lighting Cable", interface "SLP"
Cable length
3 m
Connector A
Hirose 6-pin (HR10A-7P-6S) (camera side)
Connector B
SLP-Connector (host side)
Compatible with
Lighting: Basler Camera Light Back-60x60, Basler Camera Light Ring-90OD, Basler Camera Light Ring-50OD, Basler Camera Light Ring-70OD, Basler Camera Light Bar-200x15, Basler Camera Light Flood-255x45, Basler Camera Light Bar-150x15, Basler Camera Light Bar-100x15, Basler Camera Light Back-120x120
This 3 m lead ties an ace U or L camera, through its Hirose 6-pin HR10A-7P-6S connector, to a Basler Camera Light. The compatible lights are the three Ring models (50OD, 70OD and 90OD), two Back lights (60x60 and 120x120), the Flood-255x45 and three Bar models (100x15, 150x15 and 200x15).
Length is the trade-off. A ring light fitted around the lens sits well within 3 m, but a backlight under a conveyor or a bar light mounted at an angle may come close to the limit once bends and cabinet entries are counted.
Best for
Retrofitting a Camera Light onto an existing ace U or L inspection station.
Compact stations with a ring or bar light close to the camera, where 3 m has ample reach.
Replacing a lead on a Hirose-connector camera and Camera Light combination.
Selection notes
Camera connector: Hirose 6-pin. For ace 2 or boost with M8, use SLP Cable M8 6p/TBL-S.
For an SLP Strobe Controller 121040 use SLP Cable, HRS 6p/TBL-L, P instead.
Check that your Camera Light model is one of the nine named above, then measure the cable route against the 3 m.
Specifications: General
Brand
Basler
Cable type
Lighting cable — Basler type "Lighting Cable", interface "SLP"
Compatible with
Lighting: Basler Camera Light Back-60x60, Basler Camera Light Ring-90OD, Basler Camera Light Ring-50OD, Basler Camera Light Ring-70OD, Basler Camera Light Bar-200x15, Basler Camera Light Flood-255x45, Basler Camera Light Bar-150x15, Basler Camera Light Bar-100x15, Basler Camera Light Back-120x120
Specifications: Interface
Connector A
Hirose 6-pin (HR10A-7P-6S) (camera side)
Connector B
SLP-Connector (host side)
Specifications: Mechanical
Cable length
3 m
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
The M8 version, SLP Cable M8 6p/TBL-S, because those cameras have an M8 6-pin connector.
Only if the whole route, around the frame and into the connectors, stays within 3 m. Measure it on the machine before ordering; only 3 m is available.