Basler SLP Cable M8 6p/TBL-S — lighting cable, M8 6-pin (camera side), to SLP-Connector (host side), length 3 m. Cable for connection between Basler ace 2 or boost camera and Basler Camera Light Series.
Brand
Basler
Cable type
Lighting cable — Basler type "Lighting Cable", interface "SLP"
Cable length
3 m
Connector A
M8 6-pin (camera side)
Connector B
SLP-Connector (host side)
Connection
M8 (M8 6-pin)
Compatible with
Lighting: Basler Camera Light Back-60x60, Basler Camera Light Ring-50OD, Basler Camera Light Ring-70OD, Basler Camera Light Ring-90OD, Basler Camera Light Back-120x120, Basler Camera Light Flood-255x45, Basler Camera Light Bar-100x15, Basler Camera Light Bar-150x15, Basler Camera Light Bar-200x15
This 3 m SLP cable runs from an ace 2 or boost camera's M8 6-pin connector to a Basler Camera Light. Nine Camera Light models are compatible: Ring-50OD, Ring-70OD and Ring-90OD; Back-60x60 and Back-120x120; Flood-255x45; and Bar-100x15, Bar-150x15 and Bar-200x15.
The cable does not choose the light. Ring lights give even frontal illumination but can create hot spots on gloss, backlights give silhouettes, bar lights give directional or raking light, and the flood light covers a larger area; AIS Vision can run a lighting study with your parts to choose between them. The 3 m run is camera to light, so a ring around the lens is within easy reach, while a backlight on the far side of a conveyor needs the route measured.
Best for
Ring-light inspection on ace 2 or boost, where the ring (50OD, 70OD or 90OD) sits at the lens, well within 3 m of the camera connector.
Silhouette measurement with Back-60x60 or Back-120x120, where the backlight sits across the part from the camera.
Raking or directional light with Bar-100x15, Bar-150x15 or Bar-200x15 on surface defects.
Selection notes
Camera Lights only. For an SLP Controller use SLP Cable M8 6p/TBL-L.
For a Hirose camera (ace U or L) use SLP Cable, HRS 6p/TBL-S, P.
Check that your Camera Light is one of the nine models named above.
Specifications: General
Brand
Basler
Cable type
Lighting cable — Basler type "Lighting Cable", interface "SLP"
Compatible with
Lighting: Basler Camera Light Back-60x60, Basler Camera Light Ring-50OD, Basler Camera Light Ring-70OD, Basler Camera Light Ring-90OD, Basler Camera Light Back-120x120, Basler Camera Light Flood-255x45, Basler Camera Light Bar-100x15, Basler Camera Light Bar-150x15, Basler Camera Light Bar-200x15
Specifications: Interface
Connector A
M8 6-pin (camera side)
Connector B
SLP-Connector (host side)
Connection
M8 (M8 6-pin)
Specifications: Mechanical
Cable length
3 m
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
No. This version links the camera to a Camera Light. For the SLP Strobe Controller 121040 use the SLP Cable M8 6p/TBL-L.