iRAYPLE 6-pin power & I/O cable, 6-pin female to open end with DC5.5 female jack, static — C02-IO-6PIN-DC-LC
C02-IO-6PIN-DC-LC
iRAYPLE C02-IO-6PIN-DC-LC — 6Pin Power&I/O Static Cable; End A 6-pin, Female, End B Open (With DC5.5 female); lengths 3–15 m (3, 5, 7, 10, 15 m); structure 26AWG*(2P+2C)+AB; Ø 5.2 mm; PVC jacket; min. bending radius 55 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Cable length
3–15 m (3, 5, 7, 10, 15 m)
Connector A
6-pin, Female
Connector B
Open (With DC5.5 female)
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
This is the fixed-wiring 6-pin lead with a DC5.5 female jack at the open end, in 3, 5, 7, 10 and 15 m. Every length has the same 26 AWG construction (two pairs plus two single conductors) in a 5.2 mm PVC jacket with a 55 mm minimum bending radius; the drag-chain C02-IO-6PIN-DC-FC changes to a 23 AWG pair only from 25 m, beyond the reach of this cable.
The jack gives a plug-in power input for a barrel-plug adapter, so the camera can be powered without cabinet terminals while the I/O conductors go to the controller. Barrel plugs of the same outer size come with different centre pins and polarities, so verify both on your adapter before first power-up. UL is among the cable's certifications besides RoHS2.0, which matters if the machine's approval calls for UL cable.
Best for
Fixed 6-pin cameras within 15 m of the power source, powered through a barrel-plug adapter on the DC5.5 jack.
Bench set-ups and demo rigs where the camera runs from a plug-in adapter and its I/O wires go to an open end.
Cabinet installations whose approval requires UL among the cable's certifications, which this cable carries with RoHS2.0.
Selection notes
Moving cameras need C02-IO-6PIN-DC-FC (10 million cycles); this cable is rated for static installation only.
If you do not need the jack, C02/C03-IO-6PIN has the same conductors with a plain open end and lengths from 0.6 m.
Keep the adapter output within the cable's 30 VDC maximum and match the camera's supply requirement.
Specifications: General
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
6-pin, Female
Connector B
Open (With DC5.5 female)
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–15 m (3, 5, 7, 10, 15 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
15 m. Longer 6-pin runs are available only in the drag-chain cable, up to 35 m.
Yes, for the lengths both offer (up to 15 m): 26 AWG, two pairs and two single conductors. The drag-chain cable adds a 23 AWG pair from 25 m.