iRAYPLE 12-pin power & I/O cable, 12-pin female to open end, D-elbow, static — C03-IO-12PIN(D)
C03-IO-12PIN(D)
iRAYPLE C03-IO-12PIN(D) — 12Pin Power&I/O Static Cable; End A 12-pin, Female (D elbow), End B Open; lengths 7–10 m (7, 10 m); Ø 7.0 mm; PVC jacket; min. bending radius 75 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
12Pin Power&I/O Static Cable
Cable length
7–10 m (7, 10 m)
Connector A
12-pin, Female (D elbow)
Connector B
Open
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a 12-pin power & I/O connector (power the camera, I/O signal wiring)
A right-angle exit changes how much room a camera needs behind it. End A is a 12-pin female with a D elbow, an angled plug that turns the cable at the connector instead of sending it straight out of the back. A straight plug followed by a 90° turn at the cable's 75 mm minimum bending radius needs roughly 75 mm of free depth behind the connector; elbow plugs typically make that turn inside the plug, so the camera can sit closer to a wall or housing.
The cable is the static PVC type, 7.0 mm in diameter, in 7 m and 10 m lengths, with an open end for terminals; it powers the camera and carries its I/O signals. The D, L and U variants of this family differ in the elbow, and C03-IO-12PIN(U), the static U-elbow cable, has the same lengths, jacket and radius, so the choice between the two is the elbow itself.
Best for
Cameras mounted with little free depth behind them, where a straight 12-pin plug and its bend would hit a wall, housing or neighbouring unit.
Fixed installations of 7 m or 10 m between camera and cabinet, with the cable clamped along the frame right after the connector.
Replacing an existing D-elbow lead, where the same elbow keeps the cable exit in the position the bracket and routing were built around.
Selection notes
Pick the elbow version from your mounting drawing before ordering; if you are unsure which elbow suits your camera's orientation, ask us.
Static installation only. A moving camera needs C03-IO-12PIN(L)-FC or C03-IO-12PIN(U)-FC (TPE jacket, 10 million cycles).
Only 7 m and 10 m exist. For other static lengths with a straight plug use C01/C03-IO-12PIN (3–20 m).
On a 10 m run with a power-hungry camera, confirm the conductor gauge before ordering.
Specifications: General
Brand
iRAYPLE
Cable type
12Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a 12-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
12-pin, Female (D elbow)
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
7–10 m (7, 10 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Only in the elbow variant. Both are static PVC cables of 7 m and 10 m with a 7.0 mm diameter.
The drag-chain elbow cables are the L and U types, C03-IO-12PIN(L)-FC and C03-IO-12PIN(U)-FC.