iRAYPLE 12-pin power & I/O cable, 12-pin female to open end, L-elbow, high-flex (drag chain) — C03-IO-12PIN(L)-FC
C03-IO-12PIN(L)-FC
iRAYPLE C03-IO-12PIN(L)-FC — 12Pin Power&I/O Dynamic Cable; End A 12-pin, Female (L elbow), End B Open; lengths 5–10 m (5, 7, 10 m); Ø 7.0 mm; TPE jacket; min. bending radius 75 mm; drag-chain rated (10 million cycles); operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
12Pin Power&I/O Dynamic Cable
Cable length
5–10 m (5, 7, 10 m)
Connector A
12-pin, Female (L elbow)
Connector B
Open
High-flex / drag chain
Yes — dynamic scenes (drag chain), 10 million cycles
Compatible with
Industrial cameras with a 12-pin power & I/O connector (power the camera, I/O signal wiring)
Moving cameras punish the first bend after the plug, and an elbow connector with a TPE jacket addresses it. C03-IO-12PIN(L)-FC combines an L elbow on the 12-pin female end with a 7.0 mm TPE cable rated for 10 million drag-chain cycles and a 75 mm minimum bending radius, in 5, 7 and 10 m. It powers the camera and carries its I/O signals to an open end.
Beyond the elbow the cable still has to leave the camera in a bend of at least 75 mm radius before it reaches a clamp, and it should be fixed ahead of the chain so the plug never carries the weight. TPE jackets are typically softer and more resistant to repeated flexing than PVC, which is the jacket material of the static elbow cables.
Best for
A 12-pin camera on a slide or gantry where the cable must leave the connector at an angle and then run into a chain.
Moving runs of 10 m, a length the U-elbow drag-chain cable C03-IO-12PIN(U)-FC does not reach, since it stops at 7 m.
Axes where the camera housing leaves no depth for a straight plug and a loop.
Selection notes
Match the L elbow to your mounting drawing; the U variant is the other drag-chain elbow, so ask us if you are unsure which fits your orientation.
If the camera is fixed, the static elbow cables C03-IO-12PIN(D) and C03-IO-12PIN(U) have PVC jackets and lengths of 7 m and 10 m.
If the supply margin is tight on a 10 m run, check the conductor gauge before you order.
Specifications: General
Brand
iRAYPLE
Cable type
12Pin Power&I/O Dynamic Cable
Compatible with
Industrial cameras with a 12-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
12-pin, Female (L elbow)
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
5–10 m (5, 7, 10 m)
High-flex / drag chain
Yes — dynamic scenes (drag chain), 10 million cycles
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
10 million drag-chain cycles for the cable. The plug itself is rated for ≥750 mating cycles.
Both are 12-pin, TPE, 7.0 mm, 75 mm minimum bending radius and 10 million cycles. This one has an L elbow and comes in 5, 7 and 10 m instead of 3–20 m.