iRAYPLE 6-pin power & I/O cable, 6-pin female to open end, R-elbow, static — C05-IO-6PIN(R)
C05-IO-6PIN(R)
iRAYPLE C05-IO-6PIN(R) — 6Pin Power&I/O Static Cable; End A 6-pin, Female (R elbow), End B Open; lengths 3–10 m (3, 5, 7, 10 m); structure 26AWG*(2P+2C)+AB; Ø 5.2 mm; PVC jacket; min. bending radius 55 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Cable length
3–10 m (3, 5, 7, 10 m)
Connector A
6-pin, Female (R elbow)
Connector B
Open
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Same cable as C05-IO-6PIN(L), with the R elbow on the female plug: 26AWG*(2P+2C), Ø 5.2 mm black PVC jacket, 55 mm minimum bending radius and the same four lengths, 3, 5, 7 and 10 m. The elbow version sets which way the cable leaves the connector, so look at what sits next to the camera: a bracket, light or guard on the exit side can force a bend below 55 mm, which is about 10.6 times the jacket diameter (55 ÷ 5.2).
Measure the free space on the exit side before ordering, and clamp the cable just past the first bend so that any pull is taken by the clamp, not the plug. Voltage drop grows with length on the thin 26 AWG cores: at 7 m, assuming one core out and one back, 14 m × 0.13 Ω/m ≈ 1.8 Ω (typical copper), so an example 0.5 A camera loses about 0.9 V.
Best for
Cameras whose connector side is crowded by a bracket, guard or machine wall, where the R elbow can route the cable to the free side.
Fixed installations with 3, 5, 7 or 10 m between camera and cabinet, where nothing moves the cable and static construction is enough.
Panel work where the cabinet end is terminated on site, since the open end can be cut and stripped to your own terminal layout.
Selection notes
Choose the length from the cable route, not the straight-line distance, and keep slack out of tight corners; the shortest length that reaches costs the least voltage.
A moving camera needs C05-IO-6PIN(R)-FC (5, 7 or 10 m); the chain version has no 3 m length.
Take the pin assignment from the camera manual and keep the supply within 30 VDC.
Specifications: General
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
6-pin, Female (R elbow)
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–10 m (3, 5, 7, 10 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Only the elbow version of the female plug. Lengths, the Ø 5.2 mm jacket, the 55 mm bending radius and the temperature range match C05-IO-6PIN(L).
No, this is the static version. For a chain, use C05-IO-6PIN(R)-FC, rated for 10 million drag-chain cycles.