iRAYPLE 6-pin power & I/O cable, 6-pin female to open end, D-elbow, static — C05-IO-6PIN(D)
C05-IO-6PIN(D)
iRAYPLE C05-IO-6PIN(D) — 6Pin Power&I/O Static Cable; End A 6-pin, Female (D elbow), End B Open; lengths 3–10 m (3, 5, 8, 10 m); structure 26AWG*(2P+2C)+AB; Ø 5.2 mm; PVC jacket; min. bending radius 55 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Cable length
3–10 m (3, 5, 8, 10 m)
Connector A
6-pin, Female (D elbow)
Connector B
Open
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
A D elbow on the 6-pin female end is what this lead adds to the straight static 6-pin cable C02/C03-IO-6PIN: the same 26 AWG construction (two pairs and two single conductors) in a 5.2 mm PVC jacket, the same 55 mm minimum bending radius, and the turn made inside the plug. Lengths are 3, 5, 8 and 10 m.
Without an elbow, a 55 mm bend radius needs roughly 55 mm of depth behind the connector before the cable can turn through 90°; elbow plugs typically make that turn inside the connector, which suits compact cameras mounted close to a wall or housing. The 8 m length is not offered on the straight static C02/C03-IO-6PIN, which comes in 7 m and 10 m. The cable powers the camera and carries its I/O signals to an open end.
Best for
Compact 6-pin cameras with little free depth behind the connector, where the cable must leave sideways immediately.
Fixed runs of 3, 5, 8 or 10 m to a cabinet, where the 8 m length fills the gap between the 7 m and 10 m of the straight cable.
Replacing an existing D-elbow lead, where the same elbow keeps the cable exit where the bracket was built for it.
Selection notes
Check the exit direction of the D elbow against your mounting drawing; if you are unsure it suits your orientation, ask us.
Static installation only. A moving 6-pin camera needs a drag-chain lead such as C02/C03-IO-6PIN-FC.
Wire the open end from the camera's pin table and keep the supply within the cable's 30 VDC maximum.
Specifications: General
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
6-pin, Female (D elbow)
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–10 m (3, 5, 8, 10 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
The DC5.5 jack is on C02-IO-6PIN-DC-LC (static, 3–15 m) and C02-IO-6PIN-DC-FC (drag chain, 3–35 m).
It has the D elbow on the camera end and lengths of 3, 5, 8 and 10 m. Conductors, jacket and bending radius are the same.