iRAYPLE 6-pin power & I/O cable, 6-pin female to open end, L-elbow, static — C05-IO-6PIN(L)
C05-IO-6PIN(L)
iRAYPLE C05-IO-6PIN(L) — 6Pin Power&I/O Static Cable; End A 6-pin, Female (L elbow), End B Open; lengths 3–10 m (3, 5, 7, 10 m); structure 26AWG*(2P+2C)+AB; Ø 5.2 mm; PVC jacket; min. bending radius 55 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Cable length
3–10 m (3, 5, 7, 10 m)
Connector A
6-pin, Female (L elbow)
Connector B
Open
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Power and I/O for a camera with a 6-pin connector travel in one cable: an L-elbow female plug at the camera and bare wires at the other end for the cabinet. Length costs voltage because the conductors are thin, 26 AWG, typically about 0.13 Ω/m for copper. On the 10 m version, assuming one core out and one back, 20 m × 0.13 Ω/m ≈ 2.6 Ω, so an example camera drawing 0.5 A loses 0.5 × 2.6 ≈ 1.3 V, about 11 % of a 12 V supply (1.3 ÷ 12). Check that against the camera's minimum input voltage, or take the shortest length that reaches.
This is the static construction, for cables that are clamped and never flex, with a 55 mm minimum bending radius on the Ø 5.2 mm PVC jacket. The connector is rated for at least 750 mating cycles, so treat it as wiring you plug in once and leave, not as a plug used at every changeover.
Best for
Fixed cameras on a frame or post, where the cable is clamped along its route and never flexes.
Short runs of 3 m or 5 m from a nearby cabinet, where the voltage drop on the thin 26 AWG cores stays small.
Cabinet wiring terminated on site, where the open end is cut and stripped to fit whatever terminal blocks the cabinet uses.
Selection notes
C05-IO-6PIN(R) has the same four lengths (3, 5, 7 and 10 m), jacket and 55 mm radius, so the choice between L and R comes down to which exit direction clears the camera's surroundings.
If the cable moves with the camera, take C05-IO-6PIN(L)-FC (5, 7 or 10 m, 10 million drag-chain cycles); this lead is for static scenes.
Wire the open end from the camera manual's pin table and stay within the 30 VDC rating.
Specifications: General
Brand
iRAYPLE
Cable type
6Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
6-pin, Female (L elbow)
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–10 m (3, 5, 7, 10 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
No. It is the static version; the same plug with a chain rating is C05-IO-6PIN(L)-FC, from 5 m.
Six, one for each pin: two pairs and two single cores in the 26AWG*(2P+2C) structure. The pin assignment belongs to the camera.