iRAYPLE C05-IO-6PIN(L)-FC — 6Pin Power&I/O Dynamic Cable; End A 6-pin, Female (L elbow), End B Open; lengths 5–10 m (5, 7, 10 m); structure 26AWG*(2P+2C)+AB; Ø 5.2 mm; PVC jacket; min. bending radius 55 mm; drag-chain rated (10 million cycles); operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
6Pin Power&I/O Dynamic Cable
Cable length
5–10 m (5, 7, 10 m)
Connector A
6-pin, Female (L elbow)
Connector B
Open
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Rated for 10 million drag-chain cycles, this L-elbow lead carries power and I/O to a camera that travels. In a chain the cable length is typically half the stroke plus the bend arc π × R: for an example 2 m stroke and the 55 mm minimum radius, 2 ÷ 2 + π × 0.055 ≈ 1.17 m in the chain, before the fixed runs to the cabinet and to the camera.
Against the static C05-IO-6PIN(L), the plug, the 26AWG*(2P+2C) structure, the Ø 5.2 mm PVC jacket and the 30 VDC rating are the same. What changes is the cycle rating and the length list: the chain version starts at 5 m, so a 3 m run has to be the static lead.
Best for
Cameras on a linear axis that follow a drag chain, where the L plug's exit direction clears the carriage.
Replacing a static C05-IO-6PIN(L) that fatigued on a moving axis: the camera-side plug is the same, so only the lead changes and the open end is re-terminated.
Long strokes: with an example 2 m of fixed runs at the two ends, the 10 m lead leaves 10 − 2 − π × 0.055 ≈ 7.8 m for half the stroke, a stroke of up to about 15 m.
Selection notes
C05-IO-6PIN(R)-FC offers the same 5, 7 and 10 m, and C05-IO-6PIN(D)-FC only 5 and 10 m. The electrical and cable figures are identical, so pick the elbow from the clearance around the camera.
Clamp the cable at both ends of the chain so that neither the plug nor the open-end terminations carry any pull.
Check the wire assignment in the camera manual when terminating the open end, and keep the supply within 30 VDC.
Specifications: General
Brand
iRAYPLE
Cable type
6Pin Power&I/O Dynamic Cable
Compatible with
Industrial cameras with a 6-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
6-pin, Female (L elbow)
Connector B
Open
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
5–10 m (5, 7, 10 m)
High-flex / drag chain
Yes — dynamic scene (drag chain), 10 million cycles
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Yes, a 6-pin female with the L elbow. The chain version adds the 10 million cycle rating.
No: the rating counts cycles, not travel. The stroke is set by the chain and the cable length you order, and the half-stroke-plus-arc rule above sizes the cable inside the chain.