iRAYPLE M12 12-pin power & I/O cable, M12 12pin A-code male to open end, static — CABIO-M12A12-1XX
CABIO-M12A12-1XX
iRAYPLE CABIO-M12A12-1XX — M12-12Pin Power&I/O Static Cable; End A M12 12pin A-code Male, End B Open; lengths 5–10 m (5, 10 m); structure 24AWG*12C+EB; Ø 6.5 mm; TPE jacket; min. bending radius 70 mm; static installation; operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
M12-12Pin Power&I/O Static Cable
Cable length
5–10 m (5, 10 m)
Connector A
M12 12pin A-code Male
Connector B
Open
High-flex / drag chain
No — static scenes
Compatible with
Industrial cameras with a M12 12-pin power & I/O connector (power the camera, I/O signal wiring)
Twelve single 24 AWG cores (24AWG*12C), one per pin of the M12 12-pin A-coded male plug, give a camera that brings its supply and I/O out on one M12 connector a wire for every pin. The pin-out belongs to the camera, so wire the open end from its manual. Heavier cores drop less voltage than the 26 AWG cores of the 6-pin C05-IO-6PIN(L): copper typically measures about 0.084 Ω/m at 24 AWG against 0.13 Ω/m at 26 AWG, so on 10 m, one core out and one back, 20 m × 0.084 Ω/m ≈ 1.7 Ω, or about 1.7 V at an example 1 A.
The jacket is black TPE, Ø 6.5 mm, with a 70 mm minimum bending radius (70 ÷ 6.5 ≈ 10.8 times the diameter). It is a static cable, so keep it to fixed routing. The threaded M12 coupling typically holds better against vibration and tugs than a friction-fit plug, and is rated for at least 750 mating cycles.
Best for
Cameras whose 12-pin M12 A-coded connector carries power plus several I/O lines, with each line getting its own core back to the cabinet terminals.
Frames that are touched or bumped during format changes, where a screw-locked M12 coupling resists being pulled loose.
Fixed 5 m or 10 m runs to a cabinet terminal block, where the open end is terminated on site to your own layout.
Selection notes
A camera with a 6-pin power and I/O connector takes the C05-IO-6PIN family instead; an M12 12-pin plug does not mate with a 6-pin socket.
This lead is for static routing only: for a moving camera you need a cable rated for drag-chain use.
Stay within the 30 VDC rating when wiring the open end, and allow for the voltage drop worked out above on the 10 m length.
Specifications: General
Brand
iRAYPLE
Cable type
M12-12Pin Power&I/O Static Cable
Compatible with
Industrial cameras with a M12 12-pin power & I/O connector (power the camera, I/O signal wiring)
Specifications: Interface
Connector A
M12 12pin A-code Male
Connector B
Open
Connection
M12 (camera end: M12 12pin A-code Male)
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
5–10 m (5, 10 m)
High-flex / drag chain
No — static scenes
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
No. It has 12 single 24 AWG cores and an M12 plug, against the six conductors of 26 AWG of C05-IO-6PIN(L) on a 6-pin connector, and its jacket is TPE with a 70 mm bending radius instead of PVC with 55 mm.
No, it is the static version. Use a chain-rated cable if the camera moves.