The iRAYPLE GCL-5B40E is a Camera Link frame grabber (card type: Frame grabber) with 4 camera ports. The interface is Camera Link 2.0 with 4 × SDR connectors. Bandwidth is 6.8 Gbit/s, and the host bus is PCIe 2.0 ×8 (occupies 2 PCIe slot locations). The card carries 1GB of on-board memory.
It has 10 IOs: 2× differential input (Single-end Supported), 4× Opto-isolated Input (DIN) and 4× Opto-isolated Output (DOUT). Power consumption is 9.2W (without PoCL).
Software support is Mv Viewer2.4.1 on Windows 7/8/10 64 bit. The card measures 151.1 mm × 126.3 mm × 41.9 mm, weighs 0.24kg and operates from 0 °C to +50 °C. Because it occupies 2 PCIe slot locations, slot space is the main mechanical point to check when choosing a PC.
Best for
Camera Link 2.0 stations with up to 4 camera connections on a single card
Inspection systems that need external signals through differential or opto-isolated inputs and opto-isolated outputs
Applications that use the 1GB of on-board memory of the capture card
Windows 7/8/10 64 bit vision PCs with two adjacent slot locations free and a PCIe 2.0 ×8 connector
Selection notes
The card occupies 2 PCIe slot locations (151.1 mm × 126.3 mm × 41.9 mm) and uses a PCIe 2.0 ×8 bus, so confirm that the PC has the space and the connector.
The 6.8 Gbit/s bandwidth should be compared with the combined data rate of the Camera Link cameras attached to the 4 × SDR connectors.
Match the I/O to your signals: 2× differential input (Single-end Supported), 4× Opto-isolated Input (DIN) and 4× Opto-isolated Output (DOUT).
Operating system support is Windows 7/8/10 64 bit with Mv Viewer2.4.1, and the operating temperature is 0 °C to +50 °C.
Power consumption is 9.2W (without PoCL), and the card weighs 0.24kg.
Specifications: General
Brand
iRAYPLE
Card type
Frame grabber
Specifications: Performance
Total bandwidth
6.8 Gbit/s
On-board memory
1GB
Specifications: Interface
Interface
Camera Link 2.0; SDR×4
Camera ports
4 × SDR connectors
PC bus
PCIe 2.0 ×8 (occupies 2 PCIe slot locations)
Trigger / GPIO
10 IOs up and down: 2× differential input(Single-end Supported); 4× Opto-isolated Input (DIN); 4× Opto-isolated Output (DOUT)
Specifications: Electrical
Power consumption
9.2W (without PoCL)
Specifications: Environment
Operating temperature
0 °C to +50 °C
Specifications: Software
Operating systems
Windows 7/8/10 64 bit
Software / API
Mv Viewer2.4.1
Specifications: Mechanical
Dimensions
151.1 mm × 126.3 mm × 41.9 mm
Weight
0.24kg
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
Matched automatically by: camera interface matches the card (camera link) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this card: Camera Link 2.0; SDR×4 · 4 × SDR connectors camera ports.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
It has 4 camera ports, as 4 × SDR connectors, for Camera Link 2.0.
Bandwidth is 6.8 Gbit/s on a PCIe 2.0 ×8 host bus that occupies 2 PCIe slot locations.