iRAYPLE Camera Link cable, SDR26 to SDR26, high-flex (drag chain) — C03-CL-SDR-SDR-PoCL-FC
C03-CL-SDR-SDR-PoCL-FC
iRAYPLE C03-CL-SDR-SDR-PoCL-FC — Camera Link data cable (SDR to SDR); End A SDR26, End B SDR26; lengths 3–7 m (3, 5, 7 m); structure 28AWG+ML+AL+B; Ø 9.5 mm; PVC jacket; min. bending radius 100 mm; drag-chain rated (10 million cycles); operating -20 °C to +80 °C.
Brand
iRAYPLE
Cable type
Camera Link data cable (SDR to SDR)
Cable length
3–7 m (3, 5, 7 m)
Connector A
SDR26
Connector B
SDR26
High-flex / drag chain
Yes — dynamic scenes (drag chain), 10 million cycles
A Camera Link camera needs a frame grabber at the host end, and in Base configuration one cable like this carries the whole link. A Base connection moves 24 data bits per clock at up to 85 MHz, 24 × 85 MHz ÷ 8 = 255 MB/s; as an example, a 4096-pixel, 8-bit line scan camera cannot exceed 255 MB/s ÷ 4096 B ≈ 62 kHz line rate on it. Medium and Full configurations use two cables, so those need a second lead.
Camera Link runs several LVDS pairs side by side, and the cable shows it: 9.5 mm in diameter with a 100 mm minimum bending radius, so a chain for this lead needs a generous radius. The 3, 5 and 7 m lengths are rated for 10 million drag-chain cycles and have SDR26 connectors at both ends. At 85 MHz, copper Camera Link typically reaches only about 5–7 m, so the 7 m length leaves no spare; rely on the cable maker's rating for your clock. The PoCL in the model name refers to Power over Camera Link: the camera can be powered through the cable only if camera and frame grabber both support PoCL, otherwise it needs its own supply.
Best for
Camera Link cameras on a moving axis, where the cable has to follow the motion through a chain with a radius of 100 mm or more.
Line scan or fast area scan systems that use one Camera Link connection and need 3, 5 or 7 m between camera and frame grabber.
Installations using PoCL, where one cable can replace the separate camera power lead if camera and grabber both support it.
Selection notes
Both ends are SDR26. Check that the camera and the frame grabber use SDR26 rather than the larger MDR26 connector.
A Medium or Full configuration needs two cables; this product is a single lead.
Check PoCL support on both camera and grabber before removing the camera's separate power lead.
Specifications: General
Brand
iRAYPLE
Cable type
Camera Link data cable (SDR to SDR)
Compatible with
Camera Link industrial cameras
Specifications: Interface
Connector A
SDR26
Connector B
SDR26
Specifications: Electrical
Supply voltage
30 VDC
Specifications: Environment
Operating temperature
-20 °C to +80 °C
Specifications: Mechanical
Cable length
3–7 m (3, 5, 7 m)
High-flex / drag chain
Yes — dynamic scenes (drag chain), 10 million cycles
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
This one comes in 3, 5 and 7 m. Copper Camera Link typically manages about 10 m only at low clock rates, and about 5–7 m at the full 85 MHz clock.
The model name includes PoCL, which stands for Power over Camera Link. It works only if the camera and the frame grabber both support PoCL; confirm the details with us.