FHV-VDLB2 does the same job as the straight FHV-VDB2, in the same five lengths (2, 3, 5, 10 and 20 m), but its M12 connector exits at a right angle. A straight M12 plug needs the plug body plus a bend radius of free space behind the camera; with a right-angle plug the cable runs flat along the back or side, which suits cameras fitted close to a wall, a bracket or a machine frame.
Decide the cable direction before mounting: once the camera is fixed, a right-angle exit points one way, and a guard, bracket or neighbouring camera can block it. This standard version carries no flex rating, so use it on fixed wiring; for a moving FHV7 with the same exit, see FHV-VDLBX2 (5 m only).
Best for
Cameras fitted close to a wall or panel, where there is no depth behind the connector for a straight plug.
Enclosures or brackets with limited depth, where the cable should turn immediately instead of sticking out behind the camera.
Fixed stations that need a long reach, up to 20 m, together with a compact connector exit.
Selection notes
Plan the exit direction at design time and check that the angled plug clears guards, covers and the neighbouring camera.
For a moving camera use the super bend resistant FHV-VDLBX2 (5 m) or the straight FHV-VDBX2 (5 or 10 m); beyond 5 m with a flex rating, FHV-VDBX2 is the option.
Confirm the termination of the cabinet end with us before you wire the cabinet.
Specifications: General
Brand
Omron
Cable type
Power / I/O cable
Compatible with
FHV7 (listed on Omron's FHV7 model pages; description: "FHV7")
Specifications: Interface
Connector A
M12
Connection
M12 connector
Specifications: Mechanical
Cable length
2 / 3 / 5 / 10 / 20 m
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Cable length ●
Availability
FHV7 Power / IO Cable, right angle 2 m, M12 connector Base
2 m
On request
FHV7 Power / IO Cable, right angle 3 m, M12 connector
3 m
On request
FHV7 Power / IO Cable, right angle 5 m, M12 connector
5 m
On request
FHV7 Power / IO Cable, right angle 10 m, M12 connector
10 m
On request
FHV7 Power / IO Cable, right angle 20 m, M12 connector
These steps take an Omron Sentech (STC) camera from the box to a stable first image and on to your own application. They apply across the GigE Vision, USB3 Vision and CoaXPress STC families; the interface only changes how you cable and power the camera.
Download and install the Sentech SDK on the host PC. The package provides StViewer, the viewing and configuration software you use to bring the camera up, and StApi, the programming SDK you integrate later. Because the cameras are GenICam/GenTL-compliant, StApi also registers a GenTL producer, so any GenICam-compliant third-party vision software can discover and drive the camera as an alternative front end.
2. Cable, power and connect the camera
Connect according to the interface. GigE Vision: link to a Gigabit NIC (use PoE or the separate power input) and put the camera and host on the same subnet; for USB3 Vision use a USB 3.x port and a certified cable; for CoaXPress (STC) connect to a CoaXPress frame grabber, which also supplies Power-over-Coax. Then open StViewer and let it enumerate the camera. If a GigE camera does not appear, check the IP configuration and firewall, and on USB3 confirm the host bandwidth and driver.
3. Configure exposure, gain and white balance
Open the device in StViewer and start a live stream. Set exposure and gain for a well-exposed, low-noise image: raise exposure first and only add gain when more light or a faster shutter is not an option, keeping exposure short enough to freeze motion on global-shutter models. On colour cameras, run white balance under your actual production lighting. Adjust the lens aperture and focus on a representative target before tuning anything else.
4. Set the trigger and grab a first image
Start in free-run (continuous) acquisition to confirm a clean, stable image. For inline inspection switch to hardware or software triggering: select the trigger source, set the active edge and any delay, and wire the strobe or illumination to the camera's I/O so lighting fires with each exposure. Acquire and save a frame in StViewer; this saved image is your reference for the SDK stage and for downstream inspection.
5. Move to the StApi SDK (or any GenICam software)
Once the image is stable, reproduce the same settings in code. Use StApi to open the device, apply the GenICam features you validated in StViewer (exposure, gain, trigger, pixel format) and grab frames into your application via the bundled C++, C, C#/.NET or Python interfaces; the included samples are the fastest starting point. Prefer a different stack? The same GenICam/GenTL camera works with third-party vision libraries. With a reliable feed, you can route it into a deep-learning inspection such as Rosepetal for AI-based defect detection.
Frequently asked questions
Only for the exit direction. The M12 connector and the five lengths are the same, so choose the right-angle version when space behind the camera is tight.
Yes. The Power / I/O cable does not carry the network link; the matching right-angle Ethernet cable is FHV-VNLB2, in 2 to 20 m.