The Opto Engineering RT-EX15C is a 1.5X extender for C-mount with C thread on both mount sides. It measures 37.5 mm in diameter and 6.6 mm in length, and weighs 10 g. Fitted between a C-mount lens and a C-mount camera, it raises the magnification of that lens by 1.5X, so the sensor records a larger image of the subject and the field of view narrows by the same factor. Its 6.6 mm length is the axial space it adds to the stack, and its 10 g mass places only a light load on the camera mount.
Installation is mechanical with an optical consequence. Thread the lens onto one C end and the camera onto the other, so the extender sits between them as a fixed spacer. The added length changes the focus position, so re-focus the lens after fitting and set the lens-to-part distance again from the new field of view. Check the 37.5 mm diameter against the clearance around the lens body and any bracket or housing, since the whole stack has to fit within that space.
Because the RT-EX15C changes the magnification of the lens it is fitted to, judge the finished stack as a whole rather than the lens on its own. Assemble the lens, extender and camera, then check focus and framing on the actual part before the mount is locked down. Confirm that the stack seats square on both C threads, since the threads carry the alignment of the assembly.
Best for
Raising the image scale of an existing C-mount lens and camera for closer inspection of small features, without changing the camera body.
Fixed-camera stations that need a narrower field of view on one area of a part, such as a marking or a small component.
Compact C-to-C stacks where only 6.6 mm of added axial length fits the available space.
Retrofitting an installed C-mount system that needs a 1.5X step in magnification.
Selection notes
Both mount sides are C, so the lens and the camera must both use C-mount threads; the extender does not change the mount standard.
Re-focus the lens after fitting, and set the lens-to-part distance again from the new field of view.
The 37.5 mm diameter must clear the lens body and any enclosure or bracket around the stack.
Verify focus and framing on the actual part once the extender is fitted, since the magnification has changed.