The Basler imaWorx CXP-12 Quad is a CoaXPress 2.0 frame grabber with four camera ports that allows a full bandwidth connection of up to four CXP-12 cameras. Each port is listed at 12.5 Gbit/s, for 50 Gbit/s total, and the card links to the host PC over PCIe 3.0 x8. Power over cable is PoCXP (17W/24V per connector), so cameras that accept power over CoaXPress can be supplied through the same coax link that carries their image data.
On board are a Xilinx Ultrascale+ KU3P processor and 1.5 GByte of DDR4-RAM. For external signals the card offers 12 in/10 out (max.) of I/O, TTL or opto-coupled, with differential or single-ended signals depending on configuration. Software access is through a .net interface, the Framegrabber SDK, GenTL and pylon SDKs, running on Linux 64-Bit and Windows 11 / 10 (64-Bit).
Mechanically it is a PCIe standard height, half length card of 167.64 mm length x 111.15 mm height and weighs 274 g. Typical power consumption is 13,4W@12V, excluding camera and I/O power output, and the listed operating temperature is 0 - 50 °C (32 - 122 °F).
Best for
Multi-camera CoaXPress 2.0 stations using up to four CXP-12 cameras on one PC
Software stacks that use pylon SDKs alongside GenTL, the Framegrabber SDK or a .net interface
Installations where PoCXP (17W/24V per connector) powers the cameras over the coax cable
Machines that use up to 12 inputs and 10 outputs of TTL or opto-coupled I/O on the acquisition card
Windows 11 / 10 (64-Bit) or Linux 64-Bit vision PCs with a free PCIe 3.0 x8 slot
Selection notes
A PCIe 3.0 x8 slot is required; the card is PCIe standard height, half length (167.64 mm length x 111.15 mm height).
Plan camera power outside the card's own consumption: the typical 13,4W@12V excludes camera and I/O power output, and PoCXP is listed at 17W/24V per connector.
The ports are CoaXPress (CXP-12) at 12.5 Gbit/s each, for 50 Gbit/s total across the 4 ports.
Pick the software path that fits your application: pylon SDKs, GenTL, the Framegrabber SDK and the .net interface are all listed.
The I/O signal type (TTL or opto-coupled, differential or single-ended) depends on configuration; confirm the exact setup you need in the manufacturer datasheet.
Specifications: General
Brand
Basler
Card type
Frame grabber
Specifications: Performance
Total bandwidth
50 Gbit/s total (12.5 Gbit/s per port)
On-board processing
Xilinx Ultrascale+ KU3P
On-board memory
1.5 GByte DDR4-RAM
Specifications: Interface
Interface
CoaXPress (CXP-12)
Camera ports
4
PC bus
PCIe 3.0 x8
Trigger / GPIO
12 in/10 out (max.), TTL or opto-coupled; differential or single-ended signals (configuration dependent)
Specifications: Electrical
Power over cable (PoE / PoCXP / PoCL)
PoCXP (17W/24V per connector)
Power consumption
Typ. 13,4W@12V, excluding camera and I/O power output
Matched automatically by: camera interface matches the card (coaxpress) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this card: CoaXPress (CXP-12) · 4 camera ports.
Get a first image quickly with the pylon Viewer, then move into the pylon SDK for your application. These cameras are GenICam/GenTL-compliant, so any compliant vision software can drive them as well.
Download and install the pylon Camera Software Suite for your OS from Basler. This provides the pylon Viewer, the GenTL transport-layer producers and the pylon SDK (C/C++/.NET/Python). On Windows the installer adds the needed drivers; on Linux follow the included setup notes for USB and network permissions.
2. Connect the camera and check the link
Cable the camera to its matching interface: GigE Vision to a GigE port (use a quality cable and, ideally, a dedicated NIC with jumbo frames enabled), USB3 Vision to a USB 3.x port with the supplied cable, or CoaXPress to the frame grabber. Provide power where required (PoE, USB bus power, or PoCXP). Open the pylon Viewer and confirm the camera appears in the device list; for GigE, make sure the camera and NIC are on the same subnet.
3. Grab a first image and set exposure, gain and pixel format
Select the camera in the pylon Viewer and start a continuous grab. Adjust exposure time and gain until the image is well exposed (avoid clipped highlights), set the pixel format (e.g. Mono8 or a Bayer/RGB format), and focus the lens. Use a test pattern if the lens or scene is not ready yet.
4. Configure triggering and acquisition
Decide between free-run and triggered acquisition. For synchronized capture, set the trigger source (software or a hardware line on the I/O connector), trigger mode and any debounce or exposure mode, then verify timing. Note the parameter names you change in the Viewer feature tree, as you will reuse them in code.
5. Move to the SDK or a GenICam-compliant library
Recreate your settings in code with the pylon SDK (C, C++, .NET or Python) to open the device, apply the same features and pull frames into your pipeline; pylon vTools and pylon AI can add processing blocks. Because the cameras are GenICam/GenTL standard, third-party vision libraries work too. Once the image stream is stable, you can route frames to a deep-learning inspection such as Rosepetal for automated defect detection.
Frequently asked questions
Up to four. It has 4 camera ports, each listed at 12.5 Gbit/s, for 50 Gbit/s total.
Yes, PoCXP is listed at 17W/24V per connector.
A .net interface, the Framegrabber SDK, GenTL and pylon SDKs.
Linux 64-Bit and Windows 11 / 10 (64-Bit).
A Xilinx Ultrascale+ KU3P processor and 1.5 GByte of DDR4-RAM, with 12 in/10 out (max.) of I/O.