The AH7900MU200E is a monochrome 9.0 MP area-scan camera with an IMX267 sensor, delivering 4096 x 2160 px at 3.45 µm pixel pitch with a global shutter. The sensor size is listed as 1, and the interface is USB 3.0. The listed rate is 41.6 fps for 4096 x 2160 px in Mono 8, so check the rate for other bit depths or regions of interest before sizing the system.
Power can come from the USB connector or from DC 9 V to 24 V through a Hirose connector, and the camera draws 3.6 W. The body is 29 x 44 x 58 mm and weighs 140 g, excluding lens mount and rear case connector. The listed operating range is -30 to +50 °C, which suits installations exposed to cold or hot conditions. The C-mount accepts standard C-mount lenses, and with the sensor size listed as 1, verify that each lens image circle covers the full sensor.
For a 9 MP sensor with 3.45 µm pixels, select lenses on resolution and image circle together, and plan the lighting alongside the optics so that enough detail reaches the sensor. The camera is monochrome, so color contrast has to come from lighting or filters rather than the sensor. USB 3.0 suits a direct connection to a host PC, so size the host hardware and cabling for the full 4096 x 2160 px stream.
Best for
Monochrome inspection at 4096 x 2160 px with a global shutter for moving parts.
USB 3.0 systems that connect directly to a host PC.
Installations that need a -30 to +50 °C operating range.
Gray-scale measurement across a 9 MP field of view at a listed 41.6 fps in Mono 8.
Selection notes
Confirm the frame rate for your bit depth and region of interest, since 41.6 fps is specified for Mono 8 at 4096 x 2160 px.
Choose either USB connector power or DC 9 V to 24 V via Hirose, and budget for the 3.6 W draw.
Verify USB 3.0 host and cable requirements for the full 4096 x 2160 px stream.
Check lens image circle coverage for the sensor size listed as 1.
Confirm trigger input details in the manufacturer datasheet before finalizing the cabling and triggering scheme.
Specifications: General
Brand
iRAYPLE
Camera type
Area Scan
Specifications: Sensor
Sensor model
IMX267
Sensor manufacturer
Sony
Sensor size
1
Shutter
Global
Mono / color
Mono
Resolution
9.0 MP
Horizontal resolution
4096 × 2160 px
Pixel size
3.45 μm × 3.45 μm
Specifications: Performance
FPS
41.6 fps @4096 × 2160 Mono 8
Specifications: Interface
Interface
USB 3.0
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Supply voltage
Power supply via USB connector /DC power supply by Hirose connector, with voltage range from 9V to 24V
Power consumption
3.6 W
Specifications: Environment
Operating temperature
-30℃~+50℃
Specifications: Mechanical
Dimensions
29 mm×44 mm×58 mm (not including lens mount and rear case connector)
Weight
140 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
9 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (usb3 vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: USB 3.0.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
USB 3.0.
9.0 MP at 4096 x 2160 px, with 41.6 fps in Mono 8.
It is monochrome (Mono).
USB connector power or DC 9 V to 24 V via Hirose, with a 3.6 W draw.