The iRAYPLE AH7A20MU200E uses an IMX304 sensor with a sensor size given as “1.1”, a global shutter and monochrome output. It delivers 4096 × 3000 px (12.0 MP) at up to 30.2 fps in Mono 8 over USB 3.0, so it suits inspections that need both resolution and throughput. The global shutter exposes the whole frame at once, avoiding motion distortion, and the 3.45 μm pixel pitch sets the detail the lens must resolve.
The USB 3.0 interface connects straight to a PC with a USB 3.0 port and needs no frame grabber. Power can come from the USB connection or from a DC supply of 9 V to 24 V through a Hirose connector, and the listed draw is 3.6 W. Dimensions are 29 mm × 44 mm × 58 mm (excluding lens mount and rear case connector), and the weight is 140 g. The -30 °C to +50 °C operating range suits both cold and warm cabinet environments.
For optics, the C-mount flange takes a standard C-mount lens, and the image circle must cover the sensor size given as “1.1” at 12.0 MP. This model fits inspections that need both detail and speed, such as larger parts moving under the camera at moderate rates. For very fast motion, plan strobe lighting and a trigger source that matches the exposure.
Best for
Monochrome 12.0 MP inspection at up to 30.2 fps over USB 3.0
Moving-part inspection where the global shutter avoids motion distortion
PC-based systems that use a USB 3.0 port instead of a frame grabber
Applications needing a high pixel count with a -30 °C to +50 °C operating range
Selection notes
Validate the host: the 30.2 fps figure depends on the PC, its USB 3.0 controller and the cable delivering enough bandwidth for 12 MP frames, so test it on the target hardware.
Match the rate to the task: 30.2 fps is listed for Mono 8 at the full 4096 × 3000 px, so confirm the frame rate your application needs at that resolution before sizing the USB 3.0 link.
Size the lens: the sensor size given as “1.1” needs a lens with a matching image circle, and the 3.45 μm pixels set the resolving power required.
Plan power: 3.6 W, supplied via USB or a 9 V to 24 V DC supply through the Hirose connector.
Specifications: General
Brand
iRAYPLE
Camera type
Area Scan
Specifications: Sensor
Sensor model
IMX304
Sensor manufacturer
Sony
Sensor size
1.1
Shutter
Global
Mono / color
Mono
Resolution
12.0 MP
Horizontal resolution
4096 × 3000 px
Pixel size
3.45 μm × 3.45 μm
Specifications: Performance
FPS
30.2 fps @4096 × 3000 Mono 8
Specifications: Interface
Interface
USB 3.0
Specifications: Optics
Mount
C-mount
Specifications: Electrical
Supply voltage
Power supply via USB connector /DC power supply by Hirose connector, with voltage range from 9V to 24V
Power consumption
3.6 W
Specifications: Environment
Operating temperature
-30℃~+50℃
Specifications: Mechanical
Dimensions
29 mm×44 mm×58 mm (not including lens mount and rear case connector)
Weight
140 g
Applications this product is commonly selected for. Open one to see the full recommended hardware and approach.
9 frame grabbers / interface cards are compatible with this camera.
Matched automatically by: card supports the camera interface (usb3 vision) · card link speed is at least the camera link speed (cxp-6 / cxp-12, 1–10 gige) — this camera: USB 3.0.
Follow these steps to bring up your iRAYPLE camera, capture a first image, and move from the viewer to your own application. The flow is the same across the A, AE, AX and L series; only the physical interface differs.
Download and install the iRAYPLE machine-vision SDK together with its viewer client for your operating system. The installer provides the camera drivers, the GenTL producer, and the viewer you will use for first light. For GigE Vision models, also install or enable the bundled filter/performance driver on the network adapter to maximize throughput.
2. Connect the camera to the correct interface
Wire the camera to its matching host interface: a dedicated Gigabit (or 10 GigE) NIC for GigE Vision models, a USB3 Vision port with a quality cable for USB3 models, or a frame grabber for CoaXPress models. Power the camera (PoE, USB bus power, or PoCXP / external supply as applicable). For GigE Vision, put the NIC and camera on the same subnet and, where supported, enable jumbo frames.
3. Detect and open the camera in the viewer
Launch the iRAYPLE viewer, run device enumeration, and select your camera from the discovered list. Open it to load the device feature tree (GenICam node map). If a GigE camera is found but cannot be opened, correct the IP configuration so the camera and NIC are in the same address range.
4. Set exposure, gain and trigger, then grab a first image
Start with continuous (free-run) acquisition under stable lighting. Adjust exposure time and gain for a well-exposed, low-noise image, set the pixel format (e.g. Mono8 or a Bayer/RGB format), and tune white balance on color models. Once the live image looks correct, switch trigger mode to hardware or software trigger to synchronize capture with your process, and verify a single triggered frame.
5. Move from the viewer to the SDK or a GenICam library
With imaging confirmed, reproduce the same settings in code using the SDK's C/C++ or Python API: enumerate, open, configure the relevant GenICam features, register a frame callback or grab loop, and convert frames to your pipeline's buffer format. Since the cameras are GenICam/GenTL-compliant, you can alternatively drive them from a third-party GenICam vision library. From here a stable image stream can feed a deep-learning inspection step such as Rosepetal for automated quality control.
Frequently asked questions
Up to 30.2 fps at 4096 × 3000 px in Mono 8.
No. The listed interface is USB 3.0.
An IMX304 sensor with a sensor size given as “1.1”, a global shutter and monochrome output.
3.6 W, supplied through the USB connector or a DC supply of 9 V to 24 V via a Hirose connector.