The MidOpt Bi385 Near UV Interference Bandpass Filter belongs to the Bi Series (Narrow Bandwidth Interference). Its useful range is 370–390 nm, with an FWHM (full width at half maximum) of 25 nm, which describes how narrow the passband is. The listed peak transmission is >90%, the thickness is 1mm and the surface quality is 40/20. The description states the filter can be used with 385 nm UV LED, UV fluorescent and other UV-producing lamp-based lighting.
The mount options are 25 threaded sizes from M13.25 to M82, a 25.4® C-Mount version, slip mount, and unmounted/custom sizes. Threaded and C-Mount formats hold the filter in a lens or housing in different ways, so choose the format that fits the optic you have. Because it is an interference filter, the angle of the light passing through it matters, so the mounting should hold it square to the optical axis.
In practice, the filter narrows a UV source to a band near 385 nm. That is useful when a lamp or LED emits more UV than the task needs, or when UV output has to be held to a defined band for controlled imaging or excitation. Its 370–390 nm range keeps it in the near-UV region, so it is for UV-band work rather than visible or near-infrared imaging.
Best for
UV imaging with 385 nm UV LED illumination, where the source output is held to a narrow band.
UV fluorescent or other lamp-based UV lighting that must be limited to the 370–390 nm band.
Near-UV imaging setups that need a 25 nm FWHM passband.
Lens or light housings with a C-Mount or threaded cell for a near-UV filter.
Selection notes
Match the source: confirm the illumination sits inside the 370–390 nm useful range; the description pairs the filter with 385 nm sources.
Keep the angle low: keep the light path close to normal incidence through the filter to hold the 25 nm FWHM passband.
Choose the mount: 25 threaded sizes from M13.25 to M82, 25.4® C-Mount, slip mount, or unmounted/custom sizes.
Account for the light budget and focus: peak transmission >90% and a 1mm thickness both affect exposure and focus.
Specifications: General
Brand
MidOpt
Specifications: Optical
Filter type
Bandpass
Filter wavelength
370-390nm (useful range), FWHM 25nm
Specifications: Mechanical
Thread / filter size
M13.25–M82 (25 threaded size options)
This product groups every purchasable order code that shares the same sensing method, range and output. Cable length, connector type and operation mode (Light-ON/Dark-ON, NO/NC) vary by order code below.
Family variants with highlighted differences
Model
Availability
25.4® C-Mount (threads between lens & sensor) / threaded M25.4 Base