MidOpt Bi615 Amber Interference Bandpass Filter machine vision optical filter
  • Rosepetal compatible
  • Recommended by AIS Vision

Bi615 Amber Interference Bandpass Filter

Bi615

MidOpt Bi615 Amber Interference Bandpass Filter — Bandpass filter (Bi Series - Narrow Bandwidth Interference): useful range 605-620nm, FWHM 23nm, peak transmission >90%, thickness 1mm | 2mm, surface quality 40/20. Available as 25 threaded size options (M13.25–M82), 25.4® C-Mount, slip mount, unmounted/custom sizes.

Brand
MidOpt
Filter type
Bandpass
Filter wavelength
605-620nm (useful range), FWHM 23nm
Thread / filter size
M13.25–M82 (25 threaded size options)

Technical overview

The MidOpt Bi615 Amber Interference Bandpass Filter sits in the Bi Series narrow-bandwidth line, with a useful range of 605-620nm, a FWHM of 23nm and peak transmission of >90%. The thickness is listed as 1mm | 2mm. The manufacturer says the filter is often used with 615nm LEDs, and the 615nm figure sits inside the useful range, 10nm above 605nm and 5nm below 620nm.

The useful range is 15nm wide, and the 23nm FWHM describes the passband width at half maximum. For a 615nm LED, the filter passes the amber band around the emitter and attenuates light outside it. The manufacturer also positions the filter for imaging fluorescence emissions, citing some AlphaLISA assays as an example. With peak transmission above 90%, more of the in-band light reaches the sensor, which matters when the fluorescence signal is weak.

Mechanically, the filter comes in 25 threaded size options across M13.25–M82, plus 25.4® C-Mount, slip mount, and unmounted/custom sizes. Its surface quality is 40/20. Because the thickness is listed as 1mm | 2mm, allow for that dimension when you design the holder or spacer around the filter.

Best for

  • Imaging with 615nm LEDs, where the 605-620nm useful range covers the emitter and the 23nm FWHM narrows what else reaches the sensor.
  • Imaging fluorescence emissions, such as some AlphaLISA assays, as the manufacturer describes.
  • Narrowband amber-band imaging on a lens or holder that takes one of the 25 threaded sizes from M13.25 to M82.
  • Installations where a slip mount or 25.4® C-Mount holder is preferred over a threaded fitting.

Selection notes

  • Confirm that the emitter peak falls inside 605-620nm, not only near the 615nm figure, since the window is only 15nm wide.
  • Peak transmission of >90% helps keep in-band light high, so use that figure when you set the exposure and the light budget.
  • Allow for the listed thickness of 1mm | 2mm when you design the holder or spacer around the filter.
  • Choose the thread from the 25 options across M13.25–M82 to match the lens front or holder. For a non-threaded holder, use the slip mount or 25.4® C-Mount option.

Specifications: General
BrandMidOpt

Specifications: Optical
Filter typeBandpass
Filter wavelength605-620nm (useful range), FWHM 23nm

Specifications: Mechanical
Thread / filter sizeM13.25–M82 (25 threaded size options)

Frequently asked questions

Related technical guides

Often used with

C-mount lenses

Check the lens filter thread before choosing the filter size.

All C-mount lenses →

Rosepetal · AI

Test this camera with Rosepetal

Validate your visual inspection with AI: send us sample images and we evaluate the case on your hardware.

AIS Vision · Integration

We validate camera + lens + lighting

AIS Vision defines and tests the optimal combination of camera, optics and lighting for your application before you buy.